HR_C5000
Abstract: led(0805)r HRC5000
Text: TMC Series Established Reliability TACmicrochip • • • • • • Weibull graded Reliability level: 0.1% / 1000 hrs. Low leakage CV range: 0.33-68µF / 3-20V 6 case sizes available Approved for use in life support and implantable medical devices LEAD-FREE COMPATIBLE
|
Original
|
PDF
|
100kHz
120Hz,
HR_C5000
led(0805)r
HRC5000
|
MOSFET testing
Abstract: No abstract text available
Text: V i s h ay I n t e rt e c h n o l o g y, I n c . AND TEC I INNOVAT O L OGY SMM Medical Flow N HN Power mosfets O 19 62-2012 MOSFETs - Enhanced Quality Control SMM Process Flow for Medical Implantable Applications Key Benefits • Strict manufacturing process controls result in high quality and reliability
|
Original
|
PDF
|
VMN-PT0189-1202
MOSFET testing
|
HR_C5000
Abstract: No abstract text available
Text: TMC Series Established Reliability TACmicrochip KEY FEATURES • • • • Weibull graded Reliability 0.1% / k hrs Low leakage Conformance testing Lot by Lot • Extended traceability • Approved for use in life support and implantable medical devices
|
Original
|
PDF
|
10EHS
TMCL475
010EHS
TMCR475
TMCR685
TMCH106
TMCR106
HR_C5000
|
Untitled
Abstract: No abstract text available
Text: TMC Series Established Reliability TACmicrochip KEY FEATURES • • • • Weibull graded Reliability 0.1% / k hrs Low leakage Conformance testing Lot by Lot • Extended traceability • Approved for use in life support and implantable medical devices
|
Original
|
PDF
|
15R685
010EHS
TMCH106
TMCR106
TMCA226
TMCB336
|
Untitled
Abstract: No abstract text available
Text: Implantable Medical Devices Implantable Medical Packaging SOURIAU PA&E makes it possible for medical device developers to create new, life-saving devices that are smaller, stronger, and more reliable. Our medical components are used in applications such as
|
Original
|
PDF
|
|
ZL70102
Abstract: IC TX 434 "RF Transceiver" implantable pacemaker RX 434 RF RECEIVER "Base Station Controller" Transceiver 433 block Diagram TX-400
Text: IMPLANTABLE MEDICAL RF TRANSCEIVER ZL70102 PRODUCT PREVIEW Wireless for Implantable Medical Devices Key Features The ultra low-power ZL70102 transceiver chip support a very high data rate RF radio frequency link for medical implantable communication applications. The
|
Original
|
PDF
|
ZL70102
ZL70102
10ZS175
IC TX 434
"RF Transceiver"
implantable
pacemaker
RX 434 RF RECEIVER
"Base Station Controller"
Transceiver 433 block Diagram
TX-400
|
defibrillator
Abstract: MOSFET 1000 VOLTS soft solder die bonding MSAFA1N100D MSAFA1N100DL
Text: 2830 S. Fairview Street Santa Ana, CA 92704 Phone: 714 979-8220 Fax: (714) 559-5989 DESCRIPTION: • • • • MSAFA1N100D Fast MOSFET Die for Implantable Cardio Defibrillator Applications N-Channel enhancement mode high density MOSFET die Passivation: oxynitride, 4um
|
Original
|
PDF
|
MSAFA1N100D
MSAFA1N100DL,
MSC1054
defibrillator
MOSFET 1000 VOLTS
soft solder die bonding
MSAFA1N100D
MSAFA1N100DL
|
mg03
Abstract: CC7A-T1A smd transistor t1A t1A smd micro crystal CC7A-T1A E 32.0000 C smd transistor t1A 13 t1A transistor smd transistor t1A CH-2540
Text: CC7A-T1A AT Crystal 24 MHz – 50 MHz DIMENSIONS Package: Recommended Solder Pad: 3,2 1,5 1,0 1,8 0,7 max.0,90 1,5 0,7 1,0 All dimensions in mm typical 100% leadfree, RoHS - compliant Suitable for implantable medical applications Small SMT ceramic package
|
Original
|
PDF
|
20xxxx-MG01
20xxxx-MG03
20xxxx-PG14
20xxxx-EA00
CH-2540
mg03
CC7A-T1A
smd transistor t1A
t1A smd
micro crystal CC7A-T1A
E 32.0000 C
smd transistor t1A 13
t1A transistor smd
transistor t1A
|
implantable insulin pumps
Abstract: ZARLINK zl70101 design
Text: ZL70101 Medical Implantable RF Transceiver Data Sheet Features • May 2007 Ordering Information 402-405 MHz 10 MICS channels and 433-434 MHz (2 ISM channels) ZL70101LDG1 48 pin QFN*, for base stations* (trays, bake and drypack) die, implantable grade (trays
|
Original
|
PDF
|
ZL70101
5x10-10
ZL70101UBJ
ZL70101LDG1
ZL70101UBJ)
ZL70101LDG1)
ZL70101.
implantable insulin pumps
ZARLINK
zl70101 design
|
DPAK/TO-252
Abstract: No abstract text available
Text: V i s h ay I n t e r t e c h n o l o g y, I n c . Power Mosfets SMM Medical Devices MOSFETs - Enhanced Quality Control Medical Approved Process Flow and Devices for Implantable Applications Vishay offers a growing range of approved MOSFETs that can be used for the
|
Original
|
PDF
|
Ups-2726
VMN-PL0469-1311
DPAK/TO-252
|
Untitled
Abstract: No abstract text available
Text: TMC Series Established Reliability TACmicrochip KEY FEATURES • • • • Weibull graded Reliability 0.1% / k hrs Low leakage Conformance testing Lot by Lot • Extended traceability • Approved for use in life support and implantable medical devices
|
Original
|
PDF
|
15H106
010EHS
TMCR106
TMCA226
TMCB336
TMCB476
|
k 336 16v
Abstract: No abstract text available
Text: TMC Series Established Reliability TACmicrochip • • • • • • Weibull graded Reliability 0.1% / k hrs Low leakage Conformance testing Lot by Lot Extended traceability Approved for use in life support and implantable medical devices Check for up-to-date CV Tables at
|
Original
|
PDF
|
10Vdc
16Vdc
20Vdc
k 336 16v
|
Sales
Abstract: worldwide distribution network catalog Magnetic sensors AD2220 3141L AD504
Text: Introduction NVE GMR Sensor Applications • • • • • • • • • • • Position of Pneumatic Cylinders Position in Robotics Applications Speed and Position of Bearings Speed and Position of Electric Motor Shafts General Field Detection in Implantable Medical Devices
|
Original
|
PDF
|
|
implantable insulin pumps
Abstract: ZL70101LDG1A ZL70101 QFN48 ZL70101LDG1 ZL70101UBJ ZL7010
Text: ZL70101 Medical Implantable RF Transceiver Short Form Data Sheet Features Ordering Information 402-405 MHz 10 MICS channels and 433-434 MHz (2 ISM channels) ZL70101LDG1A • High data rate (800/400/200 kbps raw data rate) • High performance MAC with automatic error
|
Original
|
PDF
|
ZL70101
ZL70101LDG1A
5x10-10
implantable insulin pumps
ZL70101LDG1A
ZL70101
QFN48
ZL70101LDG1
ZL70101UBJ
ZL7010
|
|
TX 434 RF TRANSMITTER
Abstract: "RF Transceiver" MICS pacemaker ZL70101 the circuit diagram of pacemaker IC TX 434 implantable pumps RX 434 RF RECEIVER 7ZS132
Text: MEDICAL IMPLANTABLE RF TRANSCEIVER ZL70101 PRODUCT PREVIEW The ultra low-power ZL70101 transceiver chip support a very high data rate RF radio frequency link for medical implantable communication applications. The chip’s unique design allows patient health and device performance data to be
|
Original
|
PDF
|
ZL70101
ZL70101
7ZS132
TX 434 RF TRANSMITTER
"RF Transceiver"
MICS
pacemaker
the circuit diagram of pacemaker
IC TX 434
implantable pumps
RX 434 RF RECEIVER
7ZS132
|
t1A transistor smd
Abstract: CH-2540 Micro Crystal CC1A-T1A
Text: CC7A-T1A AT Crystal 24 MHz – 30 MHz DIMENSIONS Package: Recommended Solder Pad: 3,2 1,5 1,0 1,8 0,7 max.0,90 1,5 0,7 1,0 All dimensions in mm typical 100% leadfree, RoHS - compliant Suitable for implantable medical applications Small SMT ceramic package
|
Original
|
PDF
|
CH-2540
t1A transistor smd
Micro Crystal CC1A-T1A
|
medical implantable grade pacemaker
Abstract: ZL70101 rf receiver sensitivity linearity selectivity Biomedical Engineering the circuit diagram of pacemaker 0.18-um CMOS technology characteristics Transceiver 20 GHz block Diagram
Text: Semiconductor Technology Implantable ultralow-power radio chip facilitates in-body communications Targeting implantable applications like pacemakers, nerve stimulators, drug pumps, and other such medical devices, an ultralow-power RF transceiver chip has been developed that delivers high data rates, low power consumption
|
Original
|
PDF
|
|
HR_C5000
Abstract: HRC5000 HRC-5
Text: TMC Series Established Reliability TACmicrochip KEY FEATURES • • • • Weibull graded Reliability 0.1% / k hrs Low leakage Conformance testing Lot by Lot • Extended traceability • Approved for use in life support and implantable medical devices
|
Original
|
PDF
|
|
sq4435
Abstract: SQP120N10-09
Text: V I S H AY I N T E R T E C H N O L O G Y, I N C . POWER MOSFETs SMM Medical Devices Medical Approved Process Flow and Devices for Implantable Applications Vishay offers a growing range of approved MOSFETs that can be used for the implantable medical market.
|
Original
|
PDF
|
VMN-PL0469-1505
sq4435
SQP120N10-09
|
defibrillator
Abstract: defibrillator circuit diagram phase shifter transformer charge controller using power grid block diagram "defibrillator" igbt capacitor charge pump Igbt high voltage low current
Text: Summer 2000 Issue Article A Schocking System Solution for Implantable Cardioverter Defibrillators Jonas Weiland New Business Development Micro Power Products High Voltage Half Bridge: a Breakthrough Defibrillator Module ICD Background Implantable Cardioverter Defibrillators
|
Original
|
PDF
|
MED427
Q4-2000.
defibrillator
defibrillator circuit diagram
phase shifter transformer
charge controller using power grid block diagram
"defibrillator"
igbt capacitor charge pump
Igbt high voltage low current
|
implantable insulin pumps
Abstract: zl70101 implantable medical device QFN48 ZL70101LDG1 ZL70101UBJ zl70101 design
Text: ZL70101 Medical Implantable RF Transceiver Data Sheet Features • May 2007 Ordering Information 402-405 MHz 10 MICS channels and 433-434 MHz (2 ISM channels) ZL70101LDG1 48 pin QFN*, for base stations* (trays, bake and drypack) die, implantable grade (trays
|
Original
|
PDF
|
ZL70101
ZL70101LDG1
5x10-10
ZL70101
implantable insulin pumps
implantable medical device
QFN48
ZL70101LDG1
ZL70101UBJ
zl70101 design
|
biomedical pressure sensor
Abstract: biomedical sensors biomedical sensor implanted biomedical pressure sensor MEDICAL PRESSURE die "implantable Sensor" bio-medical temperature sensor 0-300mmHg biomedical MEDICAL PRESSURE SENSOR
Text: MS763 PRESSURE SENSOR DIE 0-300 mmHg • • • • 0 to 300 mmHg range (0.4 bar or 5.8 PSI) Absolute or differential pressure sensors Medical applications RoHS-compatible & Pb-free1 DESCRIPTION The MS763 is a biomedical sensor. It has been designed as an implantable sensor where all the connections are
|
Original
|
PDF
|
MS763
MS763
MS763-S)
MS763-A)
biomedical pressure sensor
biomedical sensors
biomedical sensor
implanted biomedical pressure sensor
MEDICAL PRESSURE die
"implantable Sensor"
bio-medical temperature sensor
0-300mmHg
biomedical
MEDICAL PRESSURE SENSOR
|
Untitled
Abstract: No abstract text available
Text: CC7A-T1A AT Crystal 24 MHz – 50 MHz DIMENSIONS Package: Recommended Solder Pad: 3,2 1,5 1,0 1,8 0,7 max.0,90 1,5 0,7 1,0 All dimensions in mm typical 100% leadfree, RoHS - compliant Ultra miniature suitable for implantable medical application SMT ceramic package package height
|
Original
|
PDF
|
50MHz
20xxxx-MG01
20xxxx-MG03
20xxxx-EA00
CH-2540
|
Untitled
Abstract: No abstract text available
Text: M M1Santa Ana, A p ^CA C A _ _ • M ■ Nbcrosemi Progress Powered ly Technology 2830 S. Fairview Street Santa Ana, CA 92704 Phone: 714 979-8220 Fax: (714)559-5989 MSAFA1N100D Fast MOSFET Die for Implantable Cardio Defibrillator Applications DESCRIPTION:
|
OCR Scan
|
PDF
|
MSAFA1N100D
MSC1054
|