Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    BFM240 Search Results

    BFM240 Datasheets Context Search

    Catalog Datasheet MFG & Type Document Tags PDF

    BFM-240-13

    Abstract: No abstract text available
    Text: BFM240-13 OPERATION: The BFM range of controllers operate on a burst fire principle, over a time period of aproximately one second, offering control of resistive loads such as hotplates, heating mantles, ovens, etc. Unlike phase angle controllers the BFM generates virtually no RF interference and complies with


    Original
    BFM240-13 50/60Hz BFM-240-13 PDF

    triac burst fire control

    Abstract: TRIAC PHASE ANGLE CONTROLLER 150D BFM-240-25
    Text: Subject: bfm240_25hs_opr BFM240-25HS Burst Fired Power Controller Operation The BFM range of controllers operate on a burst fire principle, over a time period of aproximately one second, offering control of resistive loads such as hotplates,


    Original
    bfm240 20products/bfm240 BFM240-25HS 50/60Hz triac burst fire control TRIAC PHASE ANGLE CONTROLLER 150D BFM-240-25 PDF

    triac 600v 25a

    Abstract: element triac controller burst fire controller 100k lin pot BFM240-25HS BFM-240-25 BFM24
    Text: BFM240-25HS DESCRIPTION: The BFM range of controllers operate on a burst fire principle, over a time period of aproximately one second, offering control of resistive loads such as hotplates, heating mantles, ovens, etc. Unlike phase angle controllers the BFM generates virtually no RF interference and complies with European CE standards.


    Original
    BFM240-25HS 50/60Hz triac 600v 25a element triac controller burst fire controller 100k lin pot BFM240-25HS BFM-240-25 BFM24 PDF

    2kw TRIAC control

    Abstract: BFM240-25HS BFM-240-13 150D
    Text: bfm240-13/bfm240-25hs MAX. LOAD at 240V 1kW 4.0 Amps 2kW (8.5Amps) 3kW (13Amps) Page 2 sur 2 PANEL/HEATSINK RATING (at 35OC AMBIENT) 8 C/W (70 x 70 x 3mm Aluminium Panel) 4 C/W (100 x 100 x 3mm Aluminium Panel) 2 C/W (170 x 170 x 3mm Aluminium Panel) Operation


    Original
    bfm240-13/bfm240-25hs 13Amps) com/page36 50/60Hz 2kw TRIAC control BFM240-25HS BFM-240-13 150D PDF

    controlling heater with triac

    Abstract: potentiometer 100k triac burst fire control triac ts32 TRIAC heater temperature control scr for 230V AC SCR 30A 500V proportional controlling heater with triac ac regulator DATASHEET SCR
    Text: 25A VARIABLE BFM-240-25 BURST FIRED AC REGULATOR X10640 INTRODUCTION The BFM-240-25 is a mains supply, 25A ac energy regulator for proportional linear manual control of resistive loads using variable on/off bursts of complete main cycles energy, coincident with mains zero crossover. The high current triac, fuse,


    Original
    BFM-240-25 X10640 BFM-240-25 BS7671) IEC950) controlling heater with triac potentiometer 100k triac burst fire control triac ts32 TRIAC heater temperature control scr for 230V AC SCR 30A 500V proportional controlling heater with triac ac regulator DATASHEET SCR PDF

    BFM-240-13

    Abstract: BFM 15A 50Hz sine wave filter circuit boiler data sheet isolate 240v circuit-breakers BS7671 X10213 X10229 X10255
    Text: BURST FIRED AC ENERGY REGULATOR 110 to 240V @ 13A max BFM-240-13 X10638 INTRODUCTION The BFM-240-13 is a dual voltage, 13A maximum capability enclosed and compact energy regulator. It provides manual proportional power control to resistive loads by using variable bursts of energy. The burst firing circuit provides trigger pulses


    Original
    BFM-240-13 X10638 BFM-240-13 BS7671) BFM 15A 50Hz sine wave filter circuit boiler data sheet isolate 240v circuit-breakers BS7671 X10213 X10229 X10255 PDF