Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    WEIGHT TRANSDUCER FOR 1000 KG Search Results

    WEIGHT TRANSDUCER FOR 1000 KG Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    GCM188D70E226ME36D Murata Manufacturing Co Ltd Chip Multilayer Ceramic Capacitors for Automotive Visit Murata Manufacturing Co Ltd
    GRM022C71A472KE19L Murata Manufacturing Co Ltd Chip Multilayer Ceramic Capacitors for General Purpose Visit Murata Manufacturing Co Ltd
    GRM033C81A224KE01W Murata Manufacturing Co Ltd Chip Multilayer Ceramic Capacitors for General Purpose Visit Murata Manufacturing Co Ltd
    GRM155D70G475ME15D Murata Manufacturing Co Ltd Chip Multilayer Ceramic Capacitors for General Purpose Visit Murata Manufacturing Co Ltd
    GRM155R61J334KE01D Murata Manufacturing Co Ltd Chip Multilayer Ceramic Capacitors for General Purpose Visit Murata Manufacturing Co Ltd

    WEIGHT TRANSDUCER FOR 1000 KG Datasheets Context Search

    Catalog Datasheet MFG & Type PDF Document Tags

    Untitled

    Abstract: No abstract text available
    Text: THIN FILM PRESSURE TRANSDUCER FOR OIL WELL LOGGING TOOLS ULTRA HIGH LONG TERM STABILITY MADE IN USA PX3400 NIST 1395 $ mV/V Output 0-1,000 to 0-20,000 psi absolute 0-70 to 0-1,400 bar absolute Model Shown 1 bar = 14.5 psi 1 kg/cm2 = 14.22 psi 1 Atmosphere = 14.7 psi =


    Original
    PDF PX3400 F250C

    PT06A-10-6S BENDIX

    Abstract: No abstract text available
    Text: HIGH PERFORMANCE PRESSURE TRANSDUCER ULTRA HIGH LONG TERM STABILITY MADE IN USA NIST mV/V Output 0-15 to 0-10,000 psi 0-1 to 0-700 bar 1 bar = 14.5 psi 1 kg/cm2 = 14.22 psi 1 Atmosphere = 14.7 psi = 29.93 inHg = 760.2 mmHg ߜ High Shock and Vibration ߜ 100,000 Hour MTBF


    Original
    PDF PX5000 PX5003L1-100AV MS33656-4 PTS06A-10-6S, PX5000L1-5KSV-CAL11 PX5000L1-1KGV PT06A-10-6S BENDIX

    MS33649-4

    Abstract: MS33656 ms33649 MS33656 4
    Text: HIGH PERFORMANCE PRESSURE TRANSDUCER LONG TERM RELIABILITY MADE IN USA NIST PX5500 Model Shown PX5500 Series 0-5Vdc Output 0-15 to 0-10,000 psi 0-1 to 0-700 bar 1 bar = 14.5 psi 1 kg/cm2 = 14.22 psi 1 Atmosphere = 14.7 psi = 29.93 in-Hg = 760.2 mm-Hg = 1.014 bar


    Original
    PDF PX5500 PX5500 PX5500A1-015A5T PTS06A-10-6S, PX5500M1-10KG5T MS33649-4 PX5500L0-015AI-25FT MS33656-4 MS33656 ms33649 MS33656 4

    MS33649-4

    Abstract: MS33649
    Text: HIGH PERFORMANCE TRANSMITTER MADE IN USA NIST LONG TERM RELIABILITY Model PX5500L1-100GI Shown Smaller Than Actual Size PX5500 695 $ Model Shown PX5500 Series 4-20mA Output 0-15 to 0-10,000 psi 0-1 to 0-700 bar 1 bar = 14.5 psi 1 kg/cm2 = 14.22 psi 1 Atmosphere = 14.7 psi = 29.93


    Original
    PDF PX5500L1-100GI PX5500 PX5500 4-20mA PT1H-10-6P MS33656-4 MS33649-4, PTS06A-10-6S MS33649-4 MS33649

    Untitled

    Abstract: No abstract text available
    Text: THIN FILM CRYOGENIC PRESSURE TRANSDUCER MADE IN USA NIST PX1005 Model Shown PX1005 Series mV/V Output 0-15 to 0-10,000 psi 0-1 to 0-700 bar 1 bar = 14.5 psi 1 kg/cm2 = 14.22 psi 1 Atmosphere = 14.7 psi = 29.93 in-Hg = 760.2 mm-Hg = 1.014 bar Features ߜ High Performance


    Original
    PDF PX1005 PX1005 PCS06E-10-6S PX1005L1-100AV MS33656-4 PX1005L1-015SV

    Untitled

    Abstract: No abstract text available
    Text: Technologies GmbH & Co KG Open Loop Hall Current Sensor CYHCS-K3/BR This Hall Effect current sensor is based on open loop compensating principle and designed with a high galvanic isolation between primary and secondary circuits. It can be used for measurement of DC and AC current, pulse currents etc. The output of the transducer


    Original
    PDF D-85464

    Untitled

    Abstract: No abstract text available
    Text: ULTRA HIGH STABILITY THIN FILM DIFFERENTIAL PRESSURE TRANSDUCER PX1006 Series mV/V Output 0-15 to 5,000 psid 0-1 to 350 bar Differential Pressure Model PX1006D1-100DV 1350 $ Shown Actual Size MADE IN USA NIST 1 bar = 14.5 psi 1 kg/cm2 = 14.22 psi 1 Atmosphere = 14.7 psi = 29.93


    Original
    PDF PX1006 PX1006D1-100DV B-184 MS33656-4 PT1H-10-6P PT06F-10-6S PT06F-10-6S,

    Untitled

    Abstract: No abstract text available
    Text: Technologies GmbH & Co KG Open Loop Hall Current Sensor CYHCS-EA This Hall Effect current sensor is based on open loop compensating principle and designed with a high galvanic isolation between primary and secondary circuits. It can be used for measurement of DC and AC current, pulse currents etc. The output of the transducer


    Original
    PDF D-85464

    magnetic flow meter

    Abstract: GB9119-88 Flow meter LDCK-150LH10MB200F2 conductivity meter conductivity meter circuit phosphoric acid weight transducer 4-20ma flowmeter magnetic F-46
    Text: LDCK Magnetic Flow Meter Model LDCK magnetic Flow meter is composed of LDCK Magnetic Flow Transducer and LDCB F1 or F2 Magnetic Flow Converter. It can be used to measure the flow of various media in the pipes. They are corrosive liquids of acidalkali、salt,


    Original
    PDF 010mA 420mA, magnetic flow meter GB9119-88 Flow meter LDCK-150LH10MB200F2 conductivity meter conductivity meter circuit phosphoric acid weight transducer 4-20ma flowmeter magnetic F-46

    Untitled

    Abstract: No abstract text available
    Text: Technologies GmbH & Co KG Hall Effect AC/DC Current Sensor CYHCS-F1 This Hall Effect current sensor is based on open loop principle and can be used for measurement of AC/DC currents. Product Characteristics Applications • Excellent accuracy • Frequency conversion timing equipments


    Original
    PDF D-85464

    Untitled

    Abstract: No abstract text available
    Text: T 1000 PLUS Secondary Injection Relay Test Set • Designed for testing relays and transducers • Microprocessor controlled • With phase angle shifter • Frequency generator • Test results and settings are saved into local memory • High power outputs


    Original
    PDF

    100 HFK

    Abstract: No abstract text available
    Text: DATA SHEET > HFK > 20140325 HFK CAPACITIVE COUPLING CLAMP AND CALIBRATION SET CA HFK FOR TESTS ACCORDING TO . > EN 61000-4-18 > EN 61000-4-4 > IEC 61000-4-18 > IEC 61000-4-4 CALIBRATION SET FOR CAPACITIVE COUPLING CLAMP VERIFICATION The HFK is used to couple EFT/burst pulses to I/O lines as required in different European and international standards for


    Original
    PDF

    qfm64

    Abstract: RWF61 polygyr polygyr RWF61 rwf61 siemens Siemens duct temperature controller polygyr 3401 rwf61.20 enthalpy Pt 1000 sensor siemens
    Text: 1 899 1899P01 . . . . . . . . . Transducer for absolute Humidity and Enthalpy AQF61.1 Microprocessor-based converter to calculate absolute humidity, enthalpy and enthalpy differential. Application • In ventilating and air conditioning plants. • To measure, regulate, control and display absolute humidity, enthalpy or enthalpy


    Original
    PDF 1899P01 AQF61 ARG81 QFM64 RWF61. qfm64 RWF61 polygyr polygyr RWF61 rwf61 siemens Siemens duct temperature controller polygyr 3401 rwf61.20 enthalpy Pt 1000 sensor siemens

    Untitled

    Abstract: No abstract text available
    Text: High-Performance Current Transducer ITZ-S & SPR ULTRASTAB IPM = 0 . 24 kA For ultra-high precision measurement of current DC, AC, pulsed. with galvanic isolation between primary and secondary. Separate magnetic head and measuring electronics provides high


    Original
    PDF 600-PR 2000PR UT001619SH 26January2012/version M12x1

    LWGY-40A

    Abstract: LWGY-40B LWGY-10A LWGY-10B LWGY-15A LWGY-15B LWGY-25B XSF-39A PN16
    Text: Model LWGY Turbine Flow Transducer LWGY Turbine Flow Transducer called "Transducer" for short below combined with relevant flow display instruments (such as XSF-40AXSF-39A、B flow totalizers) can be used to measure the instantaneous flow rate or accumulated flow. It has found wide


    Original
    PDF XSF-40A XSF-39A JB/T9246 XSF-39B XSJ-40A SXP-3113 XSK-10B LWGY-40A LWGY-40B LWGY-10A LWGY-10B LWGY-15A LWGY-15B LWGY-25B PN16

    Untitled

    Abstract: No abstract text available
    Text: TORQ SENSE RWT410/420 series Torque Transducer SENSOR Apollo Park, Ironstone Lane, Wroxton, Banbury, Oxon, UK OX15 6AY Tel: +44 0 1869 238400 Fax: +44 (0)1869 238401 TECHNOLOGY Email: [email protected] Web: www.sensors.co.uk SENSOR TECHNOLOGY TORQ SENSE


    Original
    PDF RWT410/420 RWT410/ 420acy RWT3722R

    NAS-938

    Abstract: 180-018a NAS bolts torque chart dynamometer AP1001 410403 torque sensor rotary transformer 8311-17-10A hall sensor 6pin
    Text: - Torque Sensors Torque sensors manufactured by PCB fall into two categories of measurement: reaction torque and rotational torque. Both styles utilize strain gages, which are configured into a Wheatstone bridge circuit, as their primary sensing element. Accuracies are typically


    Original
    PDF TA-1002 TA-1003 NAS-938 180-018a NAS bolts torque chart dynamometer AP1001 410403 torque sensor rotary transformer 8311-17-10A hall sensor 6pin

    Untitled

    Abstract: No abstract text available
    Text: High-Performance Current Transducer ITZ-SB & SBPR ULTRASTAB IPM = 0 . 24 kA For ultra-high precision measurement of current DC, AC, pulsed. with galvanic isolation between primary and secondary. Separate magnetic head and measuring electronics provides high


    Original
    PDF 600-PR UT001619SH 17January2012/version M12x1

    Untitled

    Abstract: No abstract text available
    Text: TORQ SENSE RWT430/440 series Torque Transducer SENSOR Apollo Park, Ironstone Lane, Wroxton, Banbury, Oxon, UK OX15 6AY Tel: +44 0 1869 238400 Fax: +44 (0)1869 238401 Email: [email protected] Web: www.sensors.co.uk SENSOR TECHNOLOGY TORQ SENSE ® Digital RWT430/440 series Torque Transducer


    Original
    PDF RWT430/440 RWT3350R

    LF2S30N5KB6A

    Abstract: 3718401
    Text: LF2S30N5KB6A LongFellow II Linear Position Transducer, 762,0 mm [30.0 in] Electrical Travel, Binder Series 681 termination, Item Number 9810906 Features ? ? Representative photograph, actual product appearance may vary. ? ? ? Due to regional agency approval


    Original
    PDF LF2S30N5KB6A LF2S30N5KB6A 3718401

    CS5506

    Abstract: 74HC4017 DG303 equivalent X332 74HC04 AN31 CS5507 CS5509 CS5516 CS5520
    Text: AN31 Application Note A Collection of Bridge Transducer Digitizer Circuits by Jerome Johnston Introduction Bridge Transducers Bridge transducers are common in instrumentation. This application note illustrates some bridge transducer digitizer circuits which


    Original
    PDF CS5504/5/6/7/8/9 CS5516/20 AN31REV3 CS5506 74HC4017 DG303 equivalent X332 74HC04 AN31 CS5507 CS5509 CS5516 CS5520

    contrans

    Abstract: ABB LKS stk 4080 pin contrans I contrans su contrans E v28451 STK 290 010 2-84953-6 contrans V
    Text: Contrans E - SU Configurable universal transducer for all power current variables and for mains synchronization 10/28 2.54 EN • Configurable transducer for all power current variables U, I, P, Q, S, cosϕ, sinϕ, ϕ, f ■ Surface mounting case for top-hat rail mounting


    Original
    PDF 16854a Z-20010a contrans ABB LKS stk 4080 pin contrans I contrans su contrans E v28451 STK 290 010 2-84953-6 contrans V

    Untitled

    Abstract: No abstract text available
    Text: LF2S48N5KB6A LongFellow II Linear Position Transducer, 1219,2 mm [48.0 in] Electrical Travel, Binder Series 681 termination, Item Number 9810908 Features ? ? Representative photograph, actual product appearance may vary. ? ? ? Due to regional agency approval


    Original
    PDF LF2S48N5KB6A

    binder

    Abstract: Linear Position Sensors
    Text: LF2S14N5KB6A LongFellow II Linear Position Transducer, 355,6 mm [14.0 in] Electrical Travel, Binder Series 681 termination, Item Number 9810909 Features ? ? Representative photograph, actual product appearance may vary. ? ? ? Due to regional agency approval


    Original
    PDF LF2S14N5KB6A binder Linear Position Sensors