Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    TRANSDUCER TRANSFORMER Search Results

    TRANSDUCER TRANSFORMER Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    WB1040-SML Coilcraft Inc Transformer Visit Coilcraft Inc
    AS8426-A Coilcraft Inc Telecom Transformer Visit Coilcraft Inc Buy
    B0727-B Coilcraft Inc Telecom Transformer Visit Coilcraft Inc Buy
    AS8954-A Coilcraft Inc Telecom Transformer Visit Coilcraft Inc
    CR7984-CLD Coilcraft Inc Datacom Transformer Visit Coilcraft Inc

    TRANSDUCER TRANSFORMER Datasheets Context Search

    Catalog Datasheet MFG & Type PDF Document Tags

    DC220V

    Abstract: No abstract text available
    Text: Shelves transducer for transformer Model: :YDD-BC1 Name: : Shelves transducer for transformer shelves transducer for transformer 1. summarization: : this product can receive the station signals of main transformer and convert into DC simulated output by isolated. It can be applied into automatic measurement of


    Original
    PDF 1ZJ-19ZJ DC220V

    4 pin hall effect AC CURRENT

    Abstract: hall current transducer
    Text: Hall current transducer Model: :YDG-HTD-4-A Name: : Hall current transducer YDGA□/ /□ Hall Current Transducer YDG-HTDHTD-4-□A 1. Summary Aiming at the defect of big temperature drift in hall transducers, compensating circuit is adopted in order to reduce ill effect in


    Original
    PDF 020mA 420mA 05V15V020 4 pin hall effect AC CURRENT hall current transducer

    4 pin hall effect AC CURRENT

    Abstract: YDG-HTD-5-200A YDG-HTD-5-300A YDG-HTD-5-400A YDG-HTD-5-500A 5V24V
    Text: Hall current transducer Model: :YDG-HTD-5-A Name: : Hall current transducer YDGA□/ /□ Hall Current Transducer YDG-HTDHTD-5-□A 1. Summary Aiming at the defect of temperature drift in hall transducers, compensating circuit is adopted in order to reduce ill effect in


    Original
    PDF 020mA 420mA 05V15V020 4 pin hall effect AC CURRENT YDG-HTD-5-200A YDG-HTD-5-300A YDG-HTD-5-400A YDG-HTD-5-500A 5V24V

    hall current transducer

    Abstract: low current current transducer transducer
    Text: hall current transducer Model: :YDG-HTD-6-A Name: : hall current transducer YDGA□/ /□ Hall Current Transducer YDG-HTDHTD-6-□A 1. Summary Aiming at the defect of temperature drift in hall transducers, compensating circuit is adopted in order to reduce ill effect in


    Original
    PDF 020mA 420mA hall current transducer low current current transducer transducer

    hall current transducer

    Abstract: 05V15V YDG-HTD-7-500A YDG-HTD-7-300A YDG-HTD-7-600A 4 pin hall effect AC CURRENT YDG-HTD-7-800A 730* hall
    Text: hall current transducer Model: :YDG-HTD-7-A Name: : hall current transducer YDGA□/ /□ Hall Current Transducer YDG-HTDHTD-7-□A 1. Summary Aiming at the defect of temperature drift in hall transducers, compensating circuit is adopted in order to reduce ill effect in


    Original
    PDF 020mA 420mA 05V15V020 mA420 hall current transducer 05V15V YDG-HTD-7-500A YDG-HTD-7-300A YDG-HTD-7-600A 4 pin hall effect AC CURRENT YDG-HTD-7-800A 730* hall

    TMS320f2812 pwm vector code c

    Abstract: TMS320f2812 pwm vector code source TLC274N lucas schaevitz lvdt tms320f2812 program example amplitude controlled Wien Bridge Oscillator DSPG-LITE-2407 lvdt Schaevitz TMS320F2812 dc
    Text: Application Report SPRA946 - August 2003 Signal Conditioning an LVDT Using a TMS320F2812 DSP Richard Poley DSP Field Applications ABSTRACT A linear variable differential transformer LVDT is a type of electro-mechanical transducer capable of measuring linear displacement with a high degree of accuracy. The transducer


    Original
    PDF SPRA946 TMS320F2812 TMS320f2812 pwm vector code c TMS320f2812 pwm vector code source TLC274N lucas schaevitz lvdt tms320f2812 program example amplitude controlled Wien Bridge Oscillator DSPG-LITE-2407 lvdt Schaevitz TMS320F2812 dc

    transformer 220V to 24V

    Abstract: transformer YDF DC220V YDF-nKD-48V-A relay 220V DC24V DC48V
    Text: photocoulper isolated DC Model: : photocoulper isolated DC Name: : photocoulper isolated DC photocoulper isolated DC contact capacity transducer 一summarization 一、summarization YDF series contact capacity transducer is the convertor that can


    Original
    PDF beautifDF-3KD-220V-B voltageDC220Visolated 0500Vgeneral DC220V DC110V DC48V DC24V input60 input50 -1050RH95% transformer 220V to 24V transformer YDF YDF-nKD-48V-A relay 220V DC24V

    WARBLE TONE GENERATORS

    Abstract: circuit diagram of calling bell SL2418 SL2418D SL2418N ringer ic
    Text: SL2418 Telephone Tone Ringer with Bridge Diode The SL2418 is a monolithic integrated circuit telephone tone ringer with bridge diode, when coupled with an appropriate transducer, it replaces the electro-mechanical bell. The device is designed for use with either a piezo transducer or an inexpensive transformer coupled


    Original
    PDF SL2418 SL2418 WARBLE TONE GENERATORS circuit diagram of calling bell SL2418D SL2418N ringer ic

    CTSR

    Abstract: No abstract text available
    Text: Current Transducer CTSR 0.6-TP/SP2 IPRN = 600 mA For the electronic measurement of current: DC, AC, pulsed., with galvanic isolation between the primary and the secondary circuit. Applications Features Closed loop compensated current transducer Voltage output


    Original
    PDF 94-V0 4November2011/version CTSR

    Untitled

    Abstract: No abstract text available
    Text: Current Transducer CTSR 0.3-TP/SP4 IPRN = 300 mA For the electronic measurement of current: DC, AC, pulsed., with galvanic isolation between the primary and the secondary circuit. Applications Features Closed loop compensated current transducer Voltage output


    Original
    PDF 94-V0 4November2011/version

    CTSR 0.3-P

    Abstract: No abstract text available
    Text: Current Transducer CTSR 0.3-P/SP1 IPRN = 300 mA For the electronic measurement of current: DC, AC, pulsed., with galvanic isolation between the primary and the secondary circuit. Applications Features Closed loop compensated current transducer Residual current measurement


    Original
    PDF 94-V0 3November2011/version CTSR 0.3-P

    Untitled

    Abstract: No abstract text available
    Text: Current Transducer CTSR 0.6-TP/SP2 IPRN = 600 mA For the electronic measurement of current: DC, AC, pulsed., with galvanic separation between the primary circuit and the secondary circuit. Features Applications ●● Closed loop compensated current transducer


    Original
    PDF 28January2014/version

    Untitled

    Abstract: No abstract text available
    Text: Current Transducer CTSR 0.3-TP/SP4 IPRN = 300 mA For the electronic measurement of current: DC, AC, pulsed., with galvanic separation between the primary circuit and the secondary circuit. Features Applications ●● Closed loop compensated current transducer


    Original
    PDF 28January2014/version

    linear motion transducer

    Abstract: TRANSDUCER OMEGA pressure
    Text: THE LD100, A FAST LINEAR DISPLACEMENT TRANSDUCER Early in 1983, development of an electrically non-contacting linear displacement transducer LDT for use in reciprocating heater engine research began. LVDT’s in this service were unsatisfactory for several reasons. They frequently


    Original
    PDF LD100, linear motion transducer TRANSDUCER OMEGA pressure

    Untitled

    Abstract: No abstract text available
    Text: PRODUCTION DATA - SEP 03, 2012 Features ÿ ÿ ÿ ÿ ÿ ÿ ÿ ÿ ÿ ÿ ÿ ÿ ÿ ÿ ÿ ÿ General Description Stand-alone Ultrasonic Park Assist Solution Includes Driver for Ultrasonic Transducer Programmable Transducer Power Programmable Receiver Sensitivity


    Original
    PDF 16MHz 512Byte

    Untitled

    Abstract: No abstract text available
    Text: SENTINEL 3+ Battery Monitoring Transducer for Impedance, Voltage and Temperature measurements The Sentinel 3+ is a state of the art, System on Chip SoC digital transducer designed to monitor VRLA, gel or looded stationary battery systems. Data is transmitted over a dedicated


    Original
    PDF

    ctsr series

    Abstract: No abstract text available
    Text: Current Transducer CTSR series IPRN = 300, 600 mA Ref: CTSR 0.3-P, CTSR 0.6-P For the electronic measurement of current: DC, AC, pulsed., with galvanic separation between the primary circuit and the secondary circuit. Features Applications ●● Closed loop compensated current transducer


    Original
    PDF 28January2014/version ctsr series

    007B

    Abstract: Ohio Semitronics 001B 004B 008B watt transducer 005X5
    Text: AC WATT TRANSDUCER MODEL DW5- DIN RAIL MOUNTED AC WATT TRANSDUCER DESCRIPTION The Model DW5 provides power measurement to within +0.5% of reading accuracy in single or polyphase systems. The electrically isolated dc output is proportional to the instantaneous power averaged over several cycles. The DW5


    Original
    PDF 600Vac 007B Ohio Semitronics 001B 004B 008B watt transducer 005X5

    6F22 9V BATTERY

    Abstract: NEDA 1604 battery 6f22 APPA 39 Current clamp APPA 39 Battery Neda 1604 appa NEDA 1604 6F22 datasheet APPA-39R AC voltage transducer digital AC clamp meter
    Text: APPA 30 Series The State-of-the-Art Clamp-On Measuring Instruments AC CURRENT TRANSDUCER AC/DC CURRENT TRANSDUCER AC CURRENT/VOLTAGE/RESISTANCE CLAMP METER AC/DC CURRENT CLAMP METER AC/DC CURRENT CLAMP METER APPA 30 APPA 30R True-RMS reading 4000 count digital resolution


    Original
    PDF 106x240x40 66x192x27 6F22 9V BATTERY NEDA 1604 battery 6f22 APPA 39 Current clamp APPA 39 Battery Neda 1604 appa NEDA 1604 6F22 datasheet APPA-39R AC voltage transducer digital AC clamp meter

    contrans

    Abstract: ABB LKS stk 4080 pin contrans I contrans su contrans E v28451 STK 290 010 2-84953-6 contrans V
    Text: Contrans E - SU Configurable universal transducer for all power current variables and for mains synchronization 10/28 2.54 EN • Configurable transducer for all power current variables U, I, P, Q, S, cosϕ, sinϕ, ϕ, f ■ Surface mounting case for top-hat rail mounting


    Original
    PDF 16854a Z-20010a contrans ABB LKS stk 4080 pin contrans I contrans su contrans E v28451 STK 290 010 2-84953-6 contrans V

    zener diode c1

    Abstract: S1T2418D02 S1T2418G01 S1T2418G01-D0B0
    Text: TONE RINGER WITH DRIDGE DIODE S1T2418G INTRODUCTION 8−DIP−300 The S1T2418G is a monolithic integrated circuit telephone tone ringer with bridge diode. When coupled with an appropriate transducer, it replaces the electro-mechanical bell. This device is designed for use with either a piezo transducer or an


    Original
    PDF S1T2418G 8-DIP-300 S1T2418G 100nF 250Vac S1T2418G01 KA2418B/28 zener diode c1 S1T2418D02 S1T2418G01 S1T2418G01-D0B0

    din 43864 rs232 kwh

    Abstract: AA1001 SPT-90 AV7100 AA1000 CT 3-12 overload relay 20va transformer SPT-90AV51HXA1 DIN43864
    Text: Energy Management Modular Smart Power Transducer Type SPT-90 • Class 0.5 current/voltage • 16-bit µP-based modular smart power transducer • Measurements of: W, Wavg, VA, VAr, PF, Wh, VAh, VArh, Amax (among the phases), VL-L avg, VL1-N, VL2-N, VL3-N, Hz L1.


    Original
    PDF SPT-90 16-bit 20mADC mADC/10 RS232 transduc51 AO1052 AO1053 AO1054 din 43864 rs232 kwh AA1001 SPT-90 AV7100 AA1000 CT 3-12 overload relay 20va transformer SPT-90AV51HXA1 DIN43864

    SPT-DIN

    Abstract: 7segment sl1 sl2 SPTDINAV5 spt-din av3 IEC-601010 star delta triac PFL1
    Text: Energy Management Smart Power Transducer Type SPT-DIN • 16-bits µP-based smart power transducer • Measurements of: W, Wavg, VA, VAr, PF, Wh, VAh, VArh, Amax among the phases , VL-L avg, VL1-N, VL2-N, VL3-N, Hz L1. • TRMS measurement of distorted waves (voltage/current)


    Original
    PDF 16-bits DC/10 16-bit SPT-DINAV51D SPT-DIN 7segment sl1 sl2 SPTDINAV5 spt-din av3 IEC-601010 star delta triac PFL1

    bridge diode

    Abstract: KA2428 ka2418b S2-6V
    Text: KA2418B/28 TONE RINGER WITH BRIDGE DIODE INTRODUCTION Tha KA2418B/28 is a monolithic integrated circuit telephone tone ringer with bridge diode, when coupled with an appropriate transducer, it replaces the electromechanical be». This device is designed for use with either a piezo transducer or an Inexpen­


    OCR Scan
    PDF KA2418B/28 KA2418B/28 curre26 KA2418B) KA2428 27kfl 14kfl, bridge diode KA2428 ka2418b S2-6V