PLC based WATER LEVEL CONTROL
Abstract: DK9322-0809-0004 automatic water level controller project project of automatic water level controller PLC based water level controller project on automatic water level controller project on water level control Beckhoff plc of PLC based water level controller
Text: EtherCAT Application Note DK9322-0809-0004 EtherCAT Master Redundancy Keywords redundancy basis control redundancy EtherCAT master warm standby redundancy EtherCAT EtherCAT Master Redundancy - Warm Standby Control redundancy can enhance productivity and availability in critical processes. Depending on the
|
Original
|
PDF
|
DK9322-0809-0004
PLC based WATER LEVEL CONTROL
DK9322-0809-0004
automatic water level controller project
project of automatic water level controller
PLC based water level controller
project on automatic water level controller
project on water level control
Beckhoff plc
of PLC based water level controller
|
20-TdC
Abstract: 1x20A redundancy module
Text: TRIO-DIODE/12-24DC/2X10/1X20 Redundancy module INTERFACE Data sheet 104278_en_00 1 PHOENIX CONTACT 2010-04-23 Description TRIO DIODE is the DIN-rail mountable redundancy module from the TRIO POWER product range. Using the redundancy module, it is possible for two power
|
Original
|
PDF
|
TRIO-DIODE/12-24DC/2X10/1X20
20-TdC
1x20A
redundancy module
|
Untitled
Abstract: No abstract text available
Text: CRS-311 1:1 Modem Redundancy Switch Modem Accessories Overview The CRS-311 1:1 Redundancy Switch supports automatic or manual 1:1 protection for our SLM-5650A/5650 and CDM-Qx/QxL Satellite Modems. A CRS-281 IF redundancy module provides TX 70/140 MHz or L-Band backup.
|
Original
|
PDF
|
CRS-311
SLM-5650A/5650
CRS-281
modulS-281A
ds-crs311
|
0x1021
Abstract: microchip p24Fxxxx PIC24f example code lfsr galois "XOR Gates" polynomial AN-1148 CRC calculation AN1148 AN730
Text: AN1148 Cyclic Redundancy Check CRC Author: Sudhir Bommena Microchip Technology Inc. INTRODUCTION CRC is one of the most versatile error checking algorithm used in various digital communication systems. CRC stands for Cyclic Redundancy Code Check or simply Cyclic Redundancy Check.
|
Original
|
PDF
|
AN1148
DS01148A-page
0x1021
microchip p24Fxxxx
PIC24f example code
lfsr galois
"XOR Gates"
polynomial
AN-1148
CRC calculation
AN1148
AN730
|
db9f TO DB15F
Abstract: No abstract text available
Text: CRS-300 1:10 Modem Redundancy Switch Modem Accessories Overview The CRS-300 1:10 Modem Redundancy Switch provides fully automatic or manual redundancy for the following modems: CDM-570A & CDM-570AL CDM-570 & CDM-570L CDM-600 & CDM-600L CDM-625 & CDM-625A CDM-Qx & CDM-QxL
|
Original
|
PDF
|
CRS-300
CDM-570A
CDM-570AL
CDM-570
CDM-570L
CDM-600
CDM-600L
CDM-625
CDM-625A
db9f TO DB15F
|
Remote Controller with nine functions rx
Abstract: No abstract text available
Text: SNAP PAC Redundancy Option Kit Features SNAP I/O Racks PAC Redundancy Manager provides quick and intuitive configuration and monitoring SNAP-RPSW SNAP-PAC-SRA Description The SNAP PAC Redundancy Option Kit, part number SNAP-PAC-ROK, provides you the tools you need to develop a
|
Original
|
PDF
|
opto22
Remote Controller with nine functions rx
|
Untitled
Abstract: No abstract text available
Text: SNAP PAC Redundancy Option Kit Features SNAP I/O Racks PAC Redundancy Manager provides quick and intuitive configuration and monitoring SNAP-RPSW SNAP-PAC-SRA Description The SNAP PAC Redundancy Option Kit, part number SNAP-PAC-ROK, provides you the tools you need to develop a
|
Original
|
PDF
|
opto22
|
IESS-308 standard
Abstract: IESS-308 sCRAMBLER viterbi IESS-308/309 scrambler satellite v.35 DMD10 IESS-308 code IESS-308 Reed-Solomon CODEC MCS10 IESS-308/309
Text: RCS10 Modem and Redundancy Control System System Number of Modems Up to ten 10 DMD10 modem modules Back-up Modems Up to two (2) DMD10 modems may be designated as backups Possible Redundancy Configurations
|
Original
|
PDF
|
com/pdfs/Modem/BCN/RCS10s
RCS10
DMD10
RCS10/DMD10
IESS-308 standard
IESS-308 sCRAMBLER
viterbi IESS-308/309
scrambler satellite v.35
IESS-308 code
IESS-308
Reed-Solomon CODEC
MCS10
IESS-308/309
|
Untitled
Abstract: No abstract text available
Text: PRELIMINARY YRH40.245 12-28V, 40A, SINGLE REDUNDANCY MODULE Y-Series REDUNDANCY MODULE ̇ ̇ ̇ ̇ ̇ ̇ ̇ ̇ ̇ ̇ ̇ Suitable for Power Supplies with HiccupPLUS Overload Behavior Minimal Losses - Mosfets Instead of Diodes Only 150mV Voltage Drop at 40A
|
Original
|
PDF
|
YRH40
2-28V,
150mV
DS-YRH40
245-EN-preliminary
|
10209A
Abstract: 10209E RF based remote control block diagram
Text: Data Sheet, Rev. 1 September 2001 10209-Type 1:1 Redundancy Switch Units Description The 10209-type redundancy switch plug-in modules are designed to protect systems against laser, photodiode, or fiber failure. The modules can be configured according to application requirements, as indicated in
|
Original
|
PDF
|
10209-Type
DS00-300OPTO-1
DS00-300OPTO)
10209A
10209E
RF based remote control block diagram
|
Untitled
Abstract: No abstract text available
Text: YR2.DIODE DC12-48V 120V , 20A, DUAL REDUNDANCY MODULE Y-Series REDUNDANCY MODULE ̇ ̇ ̇ ̇ ̇ ̇ ̇ ̇ ̇ ̇ Cost Effective Solution to Build Redundant Systems Dual Input with Single Output Two Diodes (Common Cathode) DC12-48V (120V) ±25% Wide-range Input
|
Original
|
PDF
|
DC12-48V
|
10209A
Abstract: lucent optical switch Lucent receiver 10209E RF based remote control block diagram
Text: Data Sheet October 2000 10209-Type 1:1 Redundancy Switch Units Description The 10209-type redundancy switch plug-in modules are designed to protect for systems against laser, photodiode, or fiber failure. The modules can be configured according to application requirements, as
|
Original
|
PDF
|
10209-Type
DS00-300OPTO
10209A
lucent optical switch
Lucent receiver
10209E
RF based remote control block diagram
|
led sine board project
Abstract: ibs STME
Text: IBS ST 24 BK-FT-T INTERBUS Redundancy Module Data Sheet 5167A 5 1 6 7 A 0 0 1 05/2000 The INTERBUS redundancy module enables the creation of redundant INTERBUS systems through the double installation of the INTERBUS remote bus. It comprises two INTERBUS slaves,
|
Original
|
PDF
|
RS-232/V
led sine board project
ibs STME
|
Untitled
Abstract: No abstract text available
Text: MLY10.241 MLY-Series MiniLine-2 DC12-48V 120V , 10A, DUAL REDUNDANCY MODULE REDUNDANCY MODULE ̇ ̇ ̇ ̇ ̇ ̇ ̇ ̇ ̇ GENERAL DESCRIPTION Cost Effective Solution to Build Redundant Systems Dual Input with Single Output Two Diodes (Common Cathode) DC12-48V (120V) ±25% Wide-range Input
|
Original
|
PDF
|
MLY10
DC12-48V
DS-MLY10
241-EN
|
|
Untitled
Abstract: No abstract text available
Text: MLY02.100 MLY-Series MiniLine DC12-48V 120V , 10A, DUAL REDUNDANCY MODULE REDUNDANCY MODULE ̇ ̇ ̇ ̇ ̇ ̇ ̇ ̇ ̇ GENERAL DESCRIPTION Cost Effective Solution to Build Redundant Systems Dual Input with Single Output Two Diodes (Common Cathode) DC12-48V (120Vdc) ±25% Wide-range Input
|
Original
|
PDF
|
MLY02
DC12-48V
120Vdc)
DS-MLY02
100-EN
|
Untitled
Abstract: No abstract text available
Text: PRELIMINARY YRH40.481 24-56V, 40A, DUAL REDUNDANCY MODULE Y-Series REDUNDANCY MODULE ̇ ̇ ̇ ̇ ̇ ̇ ̇ ̇ ̇ ̇ ̇ ̇ ̇ For N+1 and 1+1 Redundant Systems Suitable for Power Supplies with HiccupPLUS Overload Behavior Dual Input with Single Output Minimal Losses - Mosfets Instead of Diodes
|
Original
|
PDF
|
YRH40
4-56V,
DS-YRH40
481-EN
|
MOSFET Module 24v 1000A
Abstract: No abstract text available
Text: PRELIMINARY YRH40.241 12-28V, 40A, DUAL REDUNDANCY MODULE Y-Series REDUNDANCY MODULE ̇ ̇ ̇ ̇ ̇ ̇ ̇ ̇ ̇ ̇ ̇ ̇ ̇ For N+1 and 1+1 Redundant Systems Suitable for Power Supplies with HiccupPLUS Overload Behavior Dual Input with Single Output Minimal Losses - Mosfets Instead of Diodes
|
Original
|
PDF
|
YRH40
2-28V,
DS-YRH40
241-EN-preliminary
MOSFET Module 24v 1000A
|
Untitled
Abstract: No abstract text available
Text: YR40.241 12-28V, 40A, DUAL REDUNDANCY MODULE Y-Series MOSFET REDUNDANCY MODULE ̇ ̇ ̇ ̇ ̇ ̇ ̇ ̇ ̇ ̇ ̇ ̇ For N+1 and 1+1 Redundant Systems Dual Input with Single Output Suitable for all Power Supplies Only 72mV Voltage Drop at 20A Output Current
|
Original
|
PDF
|
2-28V,
DS-YR40
241-EN
|
MOSFET Module 24v 1000A
Abstract: diagram Converter DC24v to 12v 10A 1x20A ZM11 EN 55011
Text: YR40.241 24-28V, 40A, DUAL REDUNDANCY MODULE Y-Series REDUNDANCY MODULE For N+1 and 1+1 Redundant Systems Dual Input with Single Output Minimal Losses - Mosfets Instead of Diodes Only 72mV Voltage Drop at 20A Output Current
|
Original
|
PDF
|
4-28V,
DS-YR40
241-EN
MOSFET Module 24v 1000A
diagram Converter DC24v to 12v 10A
1x20A
ZM11
EN 55011
|
Untitled
Abstract: No abstract text available
Text: YR80.241 12-28V, 80A, DUAL REDUNDANCY MODULE Y-Series MOSFET REDUNDANCY MODULE ̇ ̇ ̇ ̇ ̇ ̇ ̇ ̇ ̇ ̇ ̇ ̇ For N+1 and 1+1 Redundant Systems Dual Input with Single Output Suitable for all Power Supplies Only 50mV Voltage Drop at 40A Output Current
|
Original
|
PDF
|
2-28V,
DS-YR80
241-EN
|
ZM12
Abstract: No abstract text available
Text: YR80.241 24-28V, 80A, DUAL REDUNDANCY MODULE Y-Series REDUNDANCY MODULE For N+1 and 1+1 Redundant Systems Dual Input with Single Output Minimal Losses - Mosfets Instead of Diodes Only 50mV Voltage Drop at 40A Output Current
|
Original
|
PDF
|
4-28V,
DS-YR80
241-EN
ZM12
|
Synplify tmr
Abstract: CC16CE vhdl code hamming edac memory vhdl code for a grey-code counter XAPP216 voter CC16RE vhdl coding for error correction and detection algorithms vhdl code hamming RAM EDAC SEU
Text: Application Note: Virtex Series R XAPP197 v1.0 November 1, 2001 Triple Module Redundancy Design Techniques for Virtex FPGAs Author: Carl Carmichael Summary Triple Module Redundancy (TMR) combined with Single Event Upset (SEU) correction through partial reconfiguration is a powerful and effective SEU mitigation strategy. This method is only
|
Original
|
PDF
|
XAPP197
XAPP216,
XAPP216
Synplify tmr
CC16CE
vhdl code hamming edac memory
vhdl code for a grey-code counter
voter
CC16RE
vhdl coding for error correction and detection algorithms
vhdl code hamming
RAM EDAC SEU
|
Untitled
Abstract: No abstract text available
Text: PRELIMINARY YRH80.241 12-28V, 80A, DUAL REDUNDANCY MODULE Y-Series REDUNDANCY MODULE ̇ ̇ ̇ ̇ ̇ ̇ ̇ ̇ ̇ ̇ ̇ ̇ ̇ For N+1 and 1+1 Redundant Systems Suitable for Power Supplies with HiccupPLUS Overload Behavior Dual Input with Single Output Minimal Losses - Mosfets Instead of Diodes
|
Original
|
PDF
|
YRH80
2-28V,
DS-YRH80
241-EN-preliminary
|
AN220
Abstract: vhdl code hamming ecc CS61880 CS61884
Text: AN220 Application Note USING THE CS61880/CS61884 IN REDUNDANCY APPLICATIONS Figure 1 shows the block diagram for a typical T1/E1/J1 redundancy system. transmitter transformers and the termination components such as resistors and capacitors that are shared by both the primary and backup boards
|
Original
|
PDF
|
AN220
CS61880/CS61884
CS61884
AN220
vhdl code hamming ecc
CS61880
|