Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    LDC15D190A0007A MURATA Search Results

    LDC15D190A0007A MURATA Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    Murata-Type-ZY Renesas Electronics Corporation Murata Type ZY Bluetooth® Low Energy Module Visit Renesas Electronics Corporation
    Murata-Type-ZF Renesas Electronics Corporation Murata Type ZF Bluetooth® Low Energy Module Visit Renesas Electronics Corporation
    DFE2016CKA-1R0M=P2 Murata Manufacturing Co Ltd Fixed IND 1uH 1800mA NONAUTO Visit Murata Manufacturing Co Ltd
    GCM033C70J104KE02J Murata Manufacturing Co Ltd 0201 (0603M) X7S (EIA) 6.3Vdc 0.1μF±10% Visit Murata Manufacturing Co Ltd
    GRT155R61A106ME13J Murata Manufacturing Co Ltd 0402 (1005M) X5R (EIA) 10Vdc 10μF±20% Visit Murata Manufacturing Co Ltd

    LDC15D190A0007A MURATA Datasheets Context Search

    Catalog Datasheet MFG & Type PDF Document Tags

    LDC15D190A0007A Murata

    Abstract: LDC15D190A0007A AD8314 AD8314ARM AD8314ARM-REEL AD8314ARM-REEL7 AD8314-EVAL HP8116A PF0818 HP8648B
    Text: a 100 MHz–2500 MHz 45 dB RF Detector/Controller AD8314 For convenience, the signal is internally ac-coupled, using a 5 pF capacitor to a load of 3 kΩ in shunt with 2 pF. This high-pass coupling, with a corner at 16 MHz, determines the lowest operating frequency. Thus, the source may be dc-grounded.


    Original
    PDF AD8314 AD8314 C2726 LDC15D190A0007A Murata LDC15D190A0007A AD8314ARM AD8314ARM-REEL AD8314ARM-REEL7 AD8314-EVAL HP8116A PF0818 HP8648B

    branding J5A

    Abstract: J5A RM-8 LDC15D190A0007A PF08107B AD8314ARMZ AD811 AD8313 AD8314 AD8361 HP8116A
    Text: 100 MHz to 2.7 GHz, 45 dB RF Detector/Controller AD8314 For convenience, the signal is internally ac-coupled, using a 5 pF capacitor to a load of 3 kΩ in shunt with 2 pF. This highpass coupling, with a corner at approximately 16 MHz, determines the lowest operating frequency. Therefore, the


    Original
    PDF AD8314 AD8314 C01086-0-5/06 branding J5A J5A RM-8 LDC15D190A0007A PF08107B AD8314ARMZ AD811 AD8313 AD8361 HP8116A

    LDC15D190A0007A

    Abstract: fet j141 LDC15D190A0007A Murata AD8361 Picosecond Pulse Labs "logarithmic amplifier" apc ups schematic AD8314 AD8314ACP-EVAL AD8314ACP-REEL
    Text: a 100 MHz–2.7 GHz 45 dB RF Detector/Controller AD8314* For convenience, the signal is internally ac-coupled, using a 5 pF capacitor to a load of 3 kΩ in shunt with 2 pF. This high-pass coupling, with a corner at approximately 16 MHz, determines the lowest operating frequency. Thus, the source may be dc-grounded.


    Original
    PDF AD8314* AD8314 LDC15D190A0007A fet j141 LDC15D190A0007A Murata AD8361 Picosecond Pulse Labs "logarithmic amplifier" apc ups schematic AD8314ACP-EVAL AD8314ACP-REEL

    LDC15D190A0007A

    Abstract: TDS694C
    Text: a 50 dB GSM PA Controller AD8315 FEATURES Complete RF Detector/Controller Function >50 dB Range at 0.9 GHz –49 dBm to +2 dBm re 50 ⍀ Accurate Scaling from 0.1 GHz to 2.5 GHz Temperature-Stable Linear-in-dB Response Log Slope of 23 mV/dB, Intercept at –60 dBm at 0.9 GHz


    Original
    PDF AD8315 AD8315 C01520 LDC15D190A0007A TDS694C

    Untitled

    Abstract: No abstract text available
    Text: 100 MHz to 2.7 GHz, 45 dB RF Detector/Controller AD8314 For convenience, the signal is internally ac-coupled, using a 5 pF capacitor to a load of 3 kΩ in shunt with 2 pF. This highpass coupling, with a corner at approximately 16 MHz, determines the lowest operating frequency. Therefore, the


    Original
    PDF AD8314 AD8314 C01086-0-5/06

    LDC15D190A0007A

    Abstract: ad8307 AD8315 AD8316 AD8316ACP-EVAL AD8316ACP-REEL AD8316ACP-REEL7 AD8316ARM AD8316ARM-REEL AD8316ARM-REEL7
    Text: Dual Output GSM PA Controller AD8316 power control signal is required for each band. The logarithmic amplifier technique provides a much wider measurement range and better accuracy than is possible using controllers based on diode detectors. In particular, multiband and multimode cellular designs can benefit from the temperature-stable –30°C to


    Original
    PDF AD8316 C02192 LDC15D190A0007A ad8307 AD8315 AD8316 AD8316ACP-EVAL AD8316ACP-REEL AD8316ACP-REEL7 AD8316ARM AD8316ARM-REEL AD8316ARM-REEL7

    LDC15D190A0007A

    Abstract: PF08123B
    Text: 50 dB GSM PA Controller AD8311 Its high sensitivity allows control at low signal levels, thus reducing the amount of power that needs to be coupled to the detector. For convenience, the signal is internally ac-coupled. This high-pass coupling, with a corner at approximately


    Original
    PDF AD8311 AD8311 AD8311ACBZ-P7 AD8311ACBZ-P2 AD8311-EVAL D05545-0-1/11 LDC15D190A0007A PF08123B

    LDC15D190A0007A

    Abstract: CP8110 Picosecond Pulse Labs ad8307 TDS694C VZ 7 SMT03 DS345 PF08107B AD8314
    Text: 50 dB GSM PA Controller AD8315 Its high sensitivity allows control at low signal levels, thus reducing the amount of power that needs to be coupled to the detector. FEATURES Complete RF detector/controller function >50 dB range at 0.9 GHz −49 dBm to +2 dBm, re 50 Ω


    Original
    PDF AD8315 AD8315 C01520-0-6/06 LDC15D190A0007A CP8110 Picosecond Pulse Labs ad8307 TDS694C VZ 7 SMT03 DS345 PF08107B AD8314

    AD8315

    Abstract: No abstract text available
    Text: 50 dB GSM PA Controller AD8315 FEATURES Its high sensitivity allows control at low signal levels, thus reducing the amount of power that needs to be coupled to the detector. Complete RF detector/controller function >50 dB range at 0.9 GHz −49 dBm to +2 dBm, re 50 Ω


    Original
    PDF AD8315 C01520-0-6/06 AD8315

    LDC15D190A0007A

    Abstract: AD811 AD8311 AD8313 AD8314 AD8315 P6205 SMT03 TDS694C LDC15D
    Text: 50 dB GSM PA Controller AD8311 Its high sensitivity allows control at low signal levels, thus reducing the amount of power that needs to be coupled to the detector. For convenience, the signal is internally ac-coupled. This high-pass coupling, with a corner at approximately


    Original
    PDF AD8311 AD8311 AD8311ACBZ-P7 AD8311ACBZ-P2 AD8311-EVAL D05545-0-1/11 LDC15D190A0007A AD811 AD8313 AD8314 AD8315 P6205 SMT03 TDS694C LDC15D

    HPA(high power amplifier) operating at 0.1GHz

    Abstract: LDC15D190A0007A PA rectifier sma PB ka band high power fet amplifier schematic PF08107B AD8314 AD8315 P6205 SMT03 TDS694C
    Text: 50 dB GSM PA Controller AD8311 Its high sensitivity allows control at low signal levels, thus reducing the amount of power that needs to be coupled to the detector. For convenience, the signal is internally ac-coupled. This high-pass coupling, with a corner at approximately


    Original
    PDF AD8311 AD8311 AD8311ACBZ-P71 AD8311ACBZ-P21 AD8311-EVAL D05545-0-6/05 HPA(high power amplifier) operating at 0.1GHz LDC15D190A0007A PA rectifier sma PB ka band high power fet amplifier schematic PF08107B AD8314 AD8315 P6205 SMT03 TDS694C

    AD8307

    Abstract: LDC15D190A0007A AD640 AD8315 AD8315ACP-EVAL AD8315ACP-REEL AD8315ACP-REEL7 AD8315ARM AD8315ARM-REEL AD8315ARM-REEL7
    Text: 50 dB GSM PA Controller AD8315 Its high sensitivity allows control at low signal levels, thus reducing the amount of power that needs to be coupled to the detector. FEATURES Complete RF Detector/Controller Function >50 dB Range at 0.9 GHz –49 dBm to +2 dBm re 50 ⍀


    Original
    PDF AD8315 AD8315 C01520-0-1/03 AD8307 LDC15D190A0007A AD640 AD8315ACP-EVAL AD8315ACP-REEL AD8315ACP-REEL7 AD8315ARM AD8315ARM-REEL AD8315ARM-REEL7

    LDC15D190A0007A

    Abstract: ad8307 FET J134 AD8315 AD8316 AD8316ACP-EVAL AD8316ACP-REEL AD8316ACP-REEL7 AD8316ARM AD8316ARM-REEL7
    Text: Dual Output GSM PA Controller AD8316 power control signal is required for each band. The logarithmic amplifier technique provides a much wider measurement range and better accuracy than is possible using controllers based on diode detectors. In particular, multiband and multimode cellular designs can benefit from the temperature-stable –30°C to


    Original
    PDF AD8316 C02192 LDC15D190A0007A ad8307 FET J134 AD8315 AD8316 AD8316ACP-EVAL AD8316ACP-REEL AD8316ACP-REEL7 AD8316ARM AD8316ARM-REEL7

    ad8316

    Abstract: 1103PWR
    Text: Dual Output GSM PA Controller AD8316 power control signal is required for each band. The logarithmic amplifier technique provides a much wider measurement range and better accuracy than is possible using controllers based on diode detectors. In particular, multiband and multimode cellular designs can benefit from the temperature-stable –30°C to


    Original
    PDF AD8316 ad8316 1103PWR