PE Relay
Abstract: spdt 10A relay C2305A C024 60038
Text: Current and Voltage Controls 1-Phase AC/DC Over Current Type EII • AC/DC over current metering open circuit relay • Current measuring through internal shunt • 3 position rotary switch for selection of measuring range • Measuring ranges: 0.4 mA - 10 A
|
Original
|
PDF
|
|
230 volt ac overvoltage protection
Abstract: C1155A C11510A C2305A C024
Text: Current and Voltage Controls 1-Phase AC/DC Under Current Type EID • AC/DC under current metering closed circuit relay • Current measuring through internal shunt • 3 position rotary switch for selection of measuring range • Measuring ranges: 0.4 mA - 10 A
|
Original
|
PDF
|
|
EIKC024
Abstract: PE Relay 0110 PE Relay
Text: Current and Voltage Controls 1-Phase AC/DC Over Current Shunt Type EIK • AC/DC over current (open circuit) metering relay • Measuring through external shunt • 3-position rotary switch for selection of measuring range • Measuring ranges: 10-50 mV, 12-60 mV, 30-150 mV or
|
Original
|
PDF
|
|
EICC230
Abstract: shunt release circuit diagram 3 position rotary switch
Text: Current and Voltage Controls 1-Phase AC/DC Under Current Shunt Type EIC • AC/DC under current (closed circuit) metering relay • Measuring through external shunt • 3-position rotary switch for selection of measuring range • Measuring range: 10-50 mV, 12-60 mV, 30-150 mV or
|
Original
|
PDF
|
|
HIOKI 3287
Abstract: P1201A crest audio pro 8200
Text: 2014 Electrical Measuring Instruments General Catalog Recorders Data loggers Power Meters LCR Testers Battery Testers Current Probes Clamp Sensors Recorders / Data Loggers / Remote Measurement System / Component Measuring Instruments / Signal Sources / Safety Standards Measuring Instruments
|
Original
|
PDF
|
0001E52-3ZE-15K
HIOKI 3287
P1201A
crest audio pro 8200
|
coulomb counter
Abstract: future scope of wireless charging DS2761
Text: BATTERY MANAGEMENT Application Note 1798: Dec 03, 2002 Frequency Undersampling in Coulomb-Counting: Measuring Current Flow in Battery Applications Coulomb counting is a technique for measuring net current flow by counting the passing charge. It is particularly
|
Original
|
PDF
|
DS2761
DS2761:
com/an1798
coulomb counter
future scope of wireless charging
|
Untitled
Abstract: No abstract text available
Text: SICDS50V6 Current Sensors Features Hall effect measuring principle Galvanic isolation between primary and secondary circuit Low power consumption Extended measuring range Insulated plastic case recognized according to UL 94-V0 IPN = 50A
|
Original
|
PDF
|
SICDS50V6
94-V0
|
Untitled
Abstract: No abstract text available
Text: SIOLSV2 Current Sensors Features Hall effect measuring principle Galvanic isolation between primary and secondary circuit Low power consumption Extended measuring range Isolation voltage 3000V IPN = 200…2000A,Vout=±4V Advantages Industrial applications
|
Original
|
PDF
|
SIOLS200V2
SIOLS400V2
SIOLS600V2
SIOLS800V2
SIOLS1000V2
SIOLS2000V2
|
en iec 60721-3-3
Abstract: digital potentiometer for AC Digital Potentiometer 10m
Text: G2II1 5A Current measurement in 1-phase mains Reinforced insulation of the measuring circuit Measured value transmitting via standard bus Modular monitoring system Measuring range between 20mA and 5A Width 22.5mm Industrial design Technical data 1. Functions
|
Original
|
PDF
|
RS485;
en iec 60721-3-3
digital potentiometer for AC
Digital Potentiometer 10m
|
Untitled
Abstract: No abstract text available
Text: SICDS100V6 Current Sensors Features Hall effect measuring principle Galvanic isolation between primary and secondary circuit Low power consumption Extended measuring range Insulated plastic case recognized according to UL 94-V0 IPN = 50A
|
Original
|
PDF
|
SICDS100V6
94-V0
|
Untitled
Abstract: No abstract text available
Text: SIOY2CV2 Current Sensors Features Hall effect measuring principle Galvanic isolation between primary and secondary circuit Compact design for PCB mounting Low power consumption Extended measuring range 3*IPN Insulated plastic case recognized
|
Original
|
PDF
|
94-V0
|
Untitled
Abstract: No abstract text available
Text: SICF3SV2 Current Sensors Features Hall effect measuring principle Galvanic isolation between primary and secondary circuit Low power consumption Extended measuring range Insulated plastic case recognized according to UL 94-V0 IPN = 100…300A
|
Original
|
PDF
|
94-V0
|
Untitled
Abstract: No abstract text available
Text: SIOY3SV2 Current Sensors Features Hall effect measuring principle Galvanic isolation between primary and secondary circuit Isolation voltage 3000 V Low power consumption Extended measuring range 3 *IPN Insulated plastic case recognized according
|
Original
|
PDF
|
94-V0
SIOY3S400V2
SIOY3S500V2
SIOY3S600V2
SIOY3S800V2
SIOY3S1000V2
SIOY3S1200V2
SIOY3S1500V2
|
Untitled
Abstract: No abstract text available
Text: SIOT1SV2 Current Sensors Features Galvanic isolation between primary and secondary circuit Hall effect measuring principle Isolation voltage 3000V Low power consumption Extended measuring range 3*IPN Power supply from ±12V to ±15V
|
Original
|
PDF
|
SIOT1S10V2
SIOT1S15V2
SIOT1S20V2
SIOT1S25V2
SIOT1S30V2
|
|
Untitled
Abstract: No abstract text available
Text: SIOY2SV2 Current Sensors Features Hall effect measuring principle Galvanic isolation between primary and secondary circuit Compact design for PCB mounting Low power consumption Extended measuring range 3 *IPN Insulated plastic case recognized according
|
Original
|
PDF
|
94-V0
|
Untitled
Abstract: No abstract text available
Text: SIOY2L1V2 Current Sensors Features Hall effect measuring principle Galvanic isolation between primary and secondary circuit Compact design for PCB mounting Low power consumption Extended measuring range 3 *IPN Insulated plastic case recognized according
|
Original
|
PDF
|
94-V0
|
signal conditioning circuit for pt100
Abstract: PT100 temperature sensor data sheet PT100 table PT100 resistance table pt100 relay PT100 thermocouple NICR-NIal PT100 4 wire temperature sensor pt100 datasheet PT100 temperature sensor
Text: TEMPERATURE CONTROLLER MOUNTED ON A 35 mm RAIL RE60 TYPE Current flowing through Pt100 < 220 mA Measurement time 0.5 s Detection of error in the measuring circuit: - thermocouple, Pt100 overflow of the measuring range Kinds of outputs: - relay voltageless make contacts
|
Original
|
PDF
|
Pt100
Pt100
signal conditioning circuit for pt100
PT100 temperature sensor data sheet
PT100 table
PT100 resistance table
pt100 relay
PT100 thermocouple
NICR-NIal
PT100 4 wire temperature sensor
pt100 datasheet
PT100 temperature sensor
|
EUY C 400
Abstract: EUYC400 EUYC220 EUB C 400 EUY C 240
Text: Current and Voltage Controls 3-Phase True RMS, Multi-Function Type EUY • True RMS measuring on own power supply • Frequency range 45-440 Hz • Monitoring relay and 3-phased measuring relay for over/under voltage control closed circuit • Monitors phase asymmetry
|
Original
|
PDF
|
|
lem current
Abstract: LEM Components BLYT5-CNP12C4
Text: IPN = 5 A CURRENT TRANSDUCER BLYT5-CNP12C4 For the electronic measurement of AC current with a galvanic isolation between the primary circuit and secondary circuit. Electrical data Features: IPN IP ISN Va IC Vd primary nominal current primary current measuring range
|
Original
|
PDF
|
BLYT5-CNP12C4
lem current
LEM Components
BLYT5-CNP12C4
|
LA 50-P/SP1
Abstract: No abstract text available
Text: Current Transducer LA 150-P/SP1 For the electronic measurement of currents: DC, AC, pulsed., with galvanic isolation between the primary circuit and the secondary circuit. Features Electrical data IPN Primary nominal current rms IPM Primary current, measuring range
|
Original
|
PDF
|
150-P/SP1
14December2012/version
LA 50-P/SP1
|
EUD marking
Abstract: 5V SPDT relay 500V RELAY
Text: Current and Voltage Controls 1-Phase AC/DC Under Voltage Control Type EUD • AC/DC under voltage metering closed circuit relay • 3-position rotary switch for selection of measuring range • Measuring range: 20 V: 40-200 mV, 100-500 mV, 0.4-2 V or 0.4-2 V, 1-5 V, 4-20 V
|
Original
|
PDF
|
|
5V SPDT relay
Abstract: eui c 230 20v PE Relay
Text: Current and Voltage Controls 1-Phase AC/DC Over Voltage Control Type EUI • AC/DC over voltage metering open circuit relay • 3-position rotary switch for selection of measuring range • Measuring range: 20 V: 40-200 mV, 100-500 mV, 0.4-2 V or 0.4-2 V, 1-5 V, 4-20 V
|
Original
|
PDF
|
|
Current Transducer LA 25-P
Abstract: No abstract text available
Text: Current Transducer LA 125-P For the electronic measurement of currents: DC, AC, pulsed., with galvanic separation between the primary circuit and the secondary circuit. IPN = 125 A Electrical data IPN Primary nominal current rms 125 A IPM Primary current, measuring range
|
Original
|
PDF
|
125-P
23April2013/version
Current Transducer LA 25-P
|
Untitled
Abstract: No abstract text available
Text: IVTSIJBIS’-n <'.IM EAR ’Cs> HOW TO MEASURE COMPARATOR • How to Measure Comparator 1. Circuit for Measuring Circuit Current d e c 2. Circuit for Measuring Input Offset Voltage V|o ] - - - - - - - - - - - - - - - - - T-0 v cc Rl VI = 1 / 2 V c c
|
OCR Scan
|
PDF
|
|