LR42272
Abstract: Q108 1N4006 ESD Push button
Text: ACTIONI/Q Q108 DC Input Limit Alarm Provides Relay Contact Closure at a Preset DC Input Level Description The ActionI/Q model Q108 is a DIN rail mount, DC voltage or current input limit alarm with dual setpoints and two contact closure outputs. The field configurable input and alarm functions offer
|
Original
|
100mA
24VDC)
741-F
721-0717-00-D
LR42272
Q108
1N4006
ESD Push button
|
PDF
|
LR42272
Abstract: eurotherm g108 G108-0001 spdt relay 12v G108 hi g relays 1N4006 EN50081-1 relay spdt 5v 2a 5a 30vdc Relay spdt
Text: ULTRA SLIMPAK G108 DC Input Field Configurable Limit Alarm Provides Relay Contact Closures at a Preset DC Input Level Description Benefits The Ultra SlimPak G108 is a DIN rail mount, DC voltage or current input limit alarm with dual setpoints and two contact closure outputs. The field configurable input and alarm functions offer
|
Original
|
100mA
WV905
24VDC
741-F
721-0648-00-F
LR42272
eurotherm g108
G108-0001
spdt relay 12v
G108
hi g relays
1N4006
EN50081-1
relay spdt 5v 2a
5a 30vdc Relay spdt
|
PDF
|
LR42272
Abstract: Q106 1N4006
Text: ACTIONI/Q Q106 DC Input Limit Alarm Provides Relay Contact Closures at a Preset DC Input Level Description The ActionI/Q model Q106 is a DIN rail mount, DC voltage or current input limit alarm with dual setpoints and two contact closure outputs. The field configurable input and alarm functions offer
|
Original
|
100mA
741-F
721-0659-00-E
LR42272
Q106
1N4006
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Contact Closure DC Input Modules FEATURES • Wire Dry Contact Sensors Directly to Module, Eliminate External Power Supply • 2500 Vac Isolation • Built-In Status LED • UL, CSA, CE Mark, TÜV Certified TÜV not available on OpenLine • Simplifies Field Wiring
|
Original
|
70L-IDL
70G-IDC
70G-IDC24S
70G-IDC5S
|
PDF
|
70G-IDC24S
Abstract: 70G-IDC5S 70L-IDC5S EN50081-2 EN50082-2 IEC68-2-27 70L-PROG
Text: Contact Closure DC Input Modules FEATURES • Wire Dry Contact Sensors Directly to Module, Eliminate External Power Supply • 2500 Vac Isolation • Built-In Status LED • UL, CSA, CE Mark, TÜV Certified TÜV not available on OpenLine • Simplifies Field Wiring
|
Original
|
70L-IDL
70G-IDC
AC120
AC240
73G-IV50M
R3100
R4100
70G-IDC24S
70G-IDC5S
70L-IDC5S
EN50081-2
EN50082-2
IEC68-2-27
70L-PROG
|
PDF
|
Contact Closure DC Input
Abstract: dry contact 70G-IDC
Text: Contact Closure DC Input Modules FEATURES • Wire Dry Contact Sensors Directly to Module, Eliminate External Power Supply • 2500 Vac Isolation • Built-In Status LED • UL, CSA, CE Mark, TÜV Certified TÜV not available on OpenLine • Simplifies Field Wiring
|
Original
|
70L-IDL
70G-IDC
70L-IDC5S
70G-IDC5S
70G-IDC24S
Contact Closure DC Input
dry contact
70G-IDC
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Model OM-SC Portable Low Cost Datalogger Part of the NOMAD Family OM-SC 199 $ MADE IN USA ߜ Measures and Records DC Current, DC Voltage Temperature, Contact Closure and Ambient Light ߜ Time Extension Recording - Automatic Sampling up to 1 Year ߜ Automatic
|
Original
|
RS-232
RS-232
|
PDF
|
Untitled
Abstract: No abstract text available
Text: RATEMETER/TOTALIZER DPF500 Series $ 345 MADE IN USA Basic Unit ߜ Magnetic Pickup, Contact Closure, and DC Pulse Inputs Optically Isolated ߜ Displays Rate and Total Simultaneously ߜ 41⁄2-Digit Rate Display ߜ 8-Digit Totalizer Display ߜ 4-20 mA Analog Output
|
Original
|
DPF500
DPF503,
24hrs/day
|
PDF
|
DS1669-100
Abstract: ds1669-010 DS1669 DS1669-050 DS1669-10 DS1669-50 64-TO-1
Text: Dallastat TM DS1669 Electronic Digital Rheostat www.dalsemi.com FEATURES PIN ASSIGNMENT DS1669 Replaces mechanical variable resistors Electronic interface provided for digital as well as manual control Wide differential input voltage range between 4.5 and 8 volts
|
Original
|
DS1669
DS1669-10
DS1669-50
DS1669-100
DS1669
DS1669-010;
DS1669-050;
DS1669-100;
DS1669-100
ds1669-010
DS1669-050
DS1669-10
DS1669-50
64-TO-1
|
PDF
|
DS1669-010
Abstract: DS1669 DS1669-050 DS1669-10 DS1669-100 DS1669-50
Text: Dallastat TM DS1669 Electronic Digital Rheostat www.dalsemi.com FEATURES PIN ASSIGNMENT DS1669 Replaces mechanical variable resistors Electronic interface provided for digital as well as manual control Wide differential input voltage range between 4.5 and 8 volts
|
Original
|
DS1669
DS1669-10
DS1669-50
DS1669-100
DS1669
DS1669-010;
DS1669-050;
DS1669-100;
DS1669-010
DS1669-050
DS1669-10
DS1669-100
DS1669-50
|
PDF
|
ds1669
Abstract: ds1669-010
Text: Dallastat TM DS1669 Electronic Digital Rheostat www.dalsemi.com FEATURES PIN ASSIGNMENT DS1669 Replaces mechanical variable resistors Electronic interface provided for digital as well as manual control Wide differential input voltage range between 4.5 and 8 volts
|
Original
|
DS1669
DS1669-10
DS1669-50
DS1669-100
DS1669
208-mil)
DS1669-010;
DS1669-050;
DS1669-100;
ds1669-010
|
PDF
|
DS1669 IC
Abstract: DS1669 DS1669-100 DS1669-010 DS1669-050 DS1669-10 DS1669-50 DS1669S-10 DS1669S-50
Text: DS1669 Dallastat Electronic Digital Rheostat www.maxim-ic.com FEATURES § § § § § § § § § PIN ASSIGNMENT DS1669 Replaces mechanical variable resistors Electronic interface provided for digital as well as manual control Wide differential input voltage range
|
Original
|
DS1669
DS1669-10
DS1669-50
DS1669-100
DS1669-100;
DS1669 IC
DS1669
DS1669-100
DS1669-010
DS1669-050
DS1669-10
DS1669-50
DS1669S-10
DS1669S-50
|
PDF
|
FDC10 Series
Abstract: FDC10
Text: Bi-Directional Contact Closure Transceiver FDC10 SERIES INCLUDED HARDENED 1 The ComNet FDC10 Series bi-directional contact closure transceiver provides bi-directional transmission of contact closure over one multimode or single mode optical fiber. The transceiver has a contact input and a 0.5 amp contact output. The
|
Original
|
FDC10
FDC10S1A
FDC10S1B
FDC10 Series
|
PDF
|
ds1669
Abstract: DS1669S-100 ic w83 DS1669-50 DS1669-10
Text: DS1669 Dallastat Electronic Digital Rheostat www.maxim-ic.com FEATURES § § § § § § § § § PIN ASSIGNMENT DS1669 Replaces mechanical variable resistors Electronic interface provided for digital as well as manual control Wide differential input voltage range
|
Original
|
DS1669
DS1669-10
DS1669-50
DS1669-100
DS1669
208-mil)
DS1669S-10+
DS1669S-100/T
100kohms
56-G4010-001B
DS1669S-100
ic w83
DS1669-50
DS1669-10
|
PDF
|
|
AP7800
Abstract: ACTION INSTRUMENTS AP7800 eurotherm C620 MD11 Eurotherm Action
Text: ACTION PAK AP7800 MODEL Benefits ! Flexible Pulse or Contact Closure Inputs ! Eliminates Ground Loops ! Full-Scale Count Status LED ! Protects Equipment with 600V Input to Output Isolation ! ! ! Easily User Selectable Scaling Ranges: 4080 to 4 x 106 counts for F.S. Output
|
Original
|
AP7800
AP7800
4-20mA)
721-0164-00-F
ACTION INSTRUMENTS AP7800
eurotherm
C620
MD11
Eurotherm Action
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Smart Pro line interactive UPS System - NAFTA assembled version of SMART3000NET MODEL NUMBER: SM3000NAFTA Highlights 3000VA / 3kVA line interactive, extended-run tower UPS Maintains 120V nominal output over an input range of 87 to 140V Network communications
|
Original
|
SMART3000NET
SM3000NAFTA
3000VA
L5-30P
5-15/20R,
5-15R
SMART3000NET
SM3000NAFTA
WEXT3-2200-3000
2200-3000VA
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Smart Pro line interactive UPS System - NAFTA assembled version of SMART2200NET MODEL NUMBER: SM2200NAFTA Highlights 2200VA / 2.2kVA line interactive, extended-run tower UPS Maintains 120V nominal output over an input range of 87 to 140V Network communications
|
Original
|
SMART2200NET
SM2200NAFTA
2200VA
5-15P
5-15R
SM2200NAFTA
WEXT3-2200-3000
2200-3000VA
WEXT5-2200-3000
|
PDF
|
Untitled
Abstract: No abstract text available
Text: OMP-MODL Modular Portable Datalogging and Alarming System MADE IN USA From 1580 $ Basic Unit ߜ Modular Design Allows Flexibility to Meet Your Application Requirements ߜ Fully User Programmable Via Graphic Drag-andDrop Icons ߜ Expandable to 24 Universal Analog Inputs
|
Original
|
RS-232
OM-220-RPS-1
OM-220-RPS-1,
|
PDF
|
Untitled
Abstract: No abstract text available
Text: SmartOnline 5kVA On-Line Double-Conversion UPS, 4U Rack/Tower, 208/120V or 240/120V NEMA outlets, Split-phase input Highlights 5000VA / 5kVA / 3800W on-line double-conversion UPS 208/120V or 240/120V +/-3% output at 60Hz MODEL NUMBER: SU5000RT4U 4U Rack/Tower compatible;
|
Original
|
208/120V
240/120V
5000VA
240/120V
SU5000RT4U
RS232
L14-30P
L6-30R,
L6-20R
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Tripp Lite 1111 West 35th Street Chicago, IL 60609 USA Telephone: + 773 869 1234 E-mail: [email protected] Model #: SU5000RT4U SmartOnline 5kVA On-Line Double-Conversion UPS, 4U Rack/Tower, 208/120V or 240/120V NEMA outlets, Split-phase input Highlights
|
Original
|
SU5000RT4U
208/120V
240/120V
5000VA
240/120V
RS232
L14-30P
L6-30R,
L6-20R
|
PDF
|
Untitled
Abstract: No abstract text available
Text: ELECTRONIC TIMERS Electronic Timers Multi Function or Mono Function Multi Time Range Multi Voltage Large calibrated dial for easy and accurate time setting Compact Design LED indications for Input supply and Output status Surface mounting & DIN rail mounting
|
Original
|
CISPR-22
TIMER/3000/JAN
TIMER/5000/JAN
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Tripp Lite 1111 West 35th Street Chicago, IL 60609 USA Telephone: + 773 869 1234 E-mail: [email protected] Model #: SU10K3/1X SmartOnline 10kVA On-Line Double-Conversion UPS, 3 Phase Input, Single Phase Output Highlights 10,000 VA (10kVA) extended run tower UPS
|
Original
|
SU10K3/1X
10kVA
10kVA)
SU10K3/1X
module87C-1PH
|
PDF
|
8000w inverter
Abstract: No abstract text available
Text: SmartOnline 10kVA On-Line Double-Conversion UPS, 3 Phase Input, Single Phase Output Highlights 10,000 VA 10kVA extended run tower UPS MODEL NUMBER: SU10K3/1X 3-phase hardwire input (220/380, 230/400, 240/415 VAC) Single-phase hardwire output (user-selectable 220 or 230 or
|
Original
|
10kVA
10kVA)
SU10K3/1X
SU10K3/1X
BP240V787C-1PH
com/sku/SU10K3/1X.
8000w inverter
|
PDF
|
3 volt dimmer circuit
Abstract: DS1869-100 4 pin push on button push button datasheet ac dimmer Control Digital Potentiometer DS1*69 RESISTOR POTENTIOMETER 100MS DS1869
Text: DS1869 PRELIMINARY DS1869 3V DallastatTM Electronic Digital Rheostat FEATURES PIN ASSIGNMENT • Replaces mechanical variable resistors • Operates from 3V or 5V supplies • Electronic interface provided for digital as well as manual control RH 1 8 +V
|
Original
|
DS1869
DS1869
100is
3 volt dimmer circuit
DS1869-100
4 pin push on button
push button datasheet
ac dimmer
Control Digital Potentiometer
DS1*69
RESISTOR POTENTIOMETER
100MS
|
PDF
|