Untitled
Abstract: No abstract text available
Text: Conductive Sensors Level Probes Type VS2 • • • • Food and beverage usage 2 Teflon isolated electrodes For welding in container Screw connection Product Description Ordering Key Level sensor for measuring the level of conductive liquids, i.e. max./min. control
|
Original
|
PDF
|
228/1-G
S195/196,
S1961,
|
Stainless steel screw
Abstract: conductive type level sensor
Text: Level Sensors Conductive Type VS2 • • • • Product Description Level sensor for measuring the level of conductive liquids, i.e. max./min. control of charging for discharging. The function is determined by the amplifier relay used. The sensors are delivered with
|
Original
|
PDF
|
228/1-G
S195/196,
S1961,
Stainless steel screw
conductive type level sensor
|
11-pin relay pin out diagram
Abstract: No abstract text available
Text: Conductive Sensors 2-point Level Controller, Cascade Coupling Type CL with Potentiometer • Conductive level controller • Adjustment sensitivity – operating resistance from 250Ω to 500 KΩ • For filling or emptying applications • Low-voltage AC electrodes
|
Original
|
PDF
|
A/250
CLP2FA1BM24
ZPD11
11-pin relay pin out diagram
|
Untitled
Abstract: No abstract text available
Text: Conductive Sensors 2 to 4-point level controller Type CL with potentiometer • Conductive level controller • Adjustment of sensitivity – operating resistance from 250Ω to 500KΩ • Multiple combinations of filling and emptying applications • Low-voltage AC electrodes
|
Original
|
PDF
|
2x8A/250
ZPD11
|
amplifires
Abstract: relay pin out diagram H 496 166
Text: Level Sensors Amplifier, Conductive Type H 496 • Level control for conductive liquids • Max.- min. control of charging/discharging • Selection of charging or discharging by interconnection of the terminals • 3 sensitivity ranges, from 200 Ω to 220 kΩ,
|
Original
|
PDF
|
|
conductive type level sensor
Abstract: PE Relay C024
Text: Level Sensors Amplifier, Conductive Type ELC Charging , ELD (Discharging) • • • • • Level control for conductive liquids Max./min. control of charging (ELC) or discharging (ELD) Adjustable sensitivity: 10 - 100 kΩ Output: 5 A SPDT For mounting on DIN-rail in accordance with
|
Original
|
PDF
|
|
CLP2EA1CM24
Abstract: PPO NORYL vo
Text: Conductive Sensors 2-point level controller Type CL with potentiometer • • • • • Conductive level controller Sensitivity adjustment from 250 Ω to 500 KΩ For filling or emptying applications Low-voltage AC electrodes Easy installation on DIN rails or with 11 pin circular
|
Original
|
PDF
|
A/250
CLD2EA1CM24
ZPD11
CLP2EA1CM24
PPO NORYL vo
|
Untitled
Abstract: No abstract text available
Text: Conductive Sensors 1-point Basic Level Controller Type CL with Potentiometer and Time Control • • • • • • • • Conductive level controller Sensitivity adjustment 5 K0 to 150 K0 For filling or emptying applications Low-voltage AC electrodes Easy installation on DIN rails 17.5 mm
|
Original
|
PDF
|
A/250
CLD1EA1CM24
30sec.
|
ELACR11
Abstract: elacr02
Text: Level Sensors Amplifier, Conductive Type ELA Charging/Discharging • • • • • • • • • • Level control for conductive liquids Max./min. control of charging/discharging Adjustable sensitivity: 5 to 100 kΩ Output: 5 A SPDT For mounting on DIN-rail in accordance with
|
Original
|
PDF
|
|
CLP2ET1C230
Abstract: CLP2ET1CM24 CLD2ET1C230 CLD2ET1CM24 relay used water level controller CLP2ET1C115 file for WATER LEVEL CONTROLLER ZVD11 Preset 4.7K CLD2ET1C115
Text: Conductive Sensors 2-point level controller Type CL with teach-in • Conductive level controller • Teach-in of sensitivity – operating resistance from 220Ω to 220KΩ • For filling or emptying applications • Low-voltage AC electrodes • Easy installation on DIN rails or with 11 pin circular
|
Original
|
PDF
|
2x5A/250
CLD2ET1CM24
ZVD11
CLP2ET1C230
CLP2ET1CM24
CLD2ET1C230
CLD2ET1CM24
relay used water level controller
CLP2ET1C115
file for WATER LEVEL CONTROLLER
ZVD11
Preset 4.7K
CLD2ET1C115
|
7 pin relay pin out diagram
Abstract: relay pin out diagram 8 pin relay pin out diagram relay 5 pin out diagram pin diagram of 8 pin relay 12 volt 6 pin relay 6 volt relay pin out diagram conductive type level sensor 5 pin relay connection 11 pin relay base
Text: Level Sensors Amplifier, Conductive Type S 197 Charging/Discharging • Controller for conductive liquids • Controls minimum/maximum and indicates over and under alarm • Filling or emptying function selectable • Fixed sentitivity • 2 x 5 A 250 VAC relay outputs, SPST
|
Original
|
PDF
|
|
VOLTAGE LEVEL RELAY SM 125 220
Abstract: VOLTAGE LEVEL RELAY SM 125 220 156 VOLTAGE LEVEL RELAY SM 125 230 siemens IEC 60947-5-1 RELAY CASCADING 5 pins relay pin diagram FRS2 relay 5 pin out diagram siemens relay pins 6 volt relay pin out diagram
Text: Level Sensors Charging or Discharging Type S 1961 • Level control for conductive liquids • Max.- min. control of charging/discharging • Selection of charging or discharging by interconnection of the pins • 3 sensitivity ranges, from 200 Ω to 220 kΩ,
|
Original
|
PDF
|
|
water level control relay diagram
Abstract: S194 capacitive level sensor conductive type level sensor 166 relay RELAY-DPDT 156 relay elect relay water level inductive sensor capacitive water sensor
Text: Level Sensors Amplifier, Conductive/Capacitive Types S 194, H 494 Charging • • • • • S 194 Control of CHARGING (swimming pools) S 194 Output: 10 A SPDT relay H 494 Output: 8 A DPDT relay LED-indications: Power supply and relay ON AC power supply
|
Original
|
PDF
|
11-pin
water level control relay diagram
S194
capacitive level sensor
conductive type level sensor
166 relay
RELAY-DPDT
156 relay
elect relay
water level inductive sensor
capacitive water sensor
|
titanium chloride
Abstract: RCU-7000 hydrochloric acid
Text: ELS Series – Conductive Level Sensors • Operational Description ■ ELS Series Conductive Electrode Level Sensors ■ Usable in a wide range of liquids ■ Up to 7 pole configuration ■ Safe low voltage and small currents ■ Switch points easily adjusted in
|
Original
|
PDF
|
RCU7000
10K4B,
316SS
com/6259
titanium chloride
RCU-7000
hydrochloric acid
|
|
973CP15TM-A11T-L
Abstract: 972CP15TM-A13P-L capacitive sensor water level detection 972CP8TM-A13P-L 925CPWL-30 973CP15TM-B11T-L Honeywell Proximity Sensors 972 973CP15TP-A11T-L B124 972CP15TM-A13N-L
Text: Proximity Sensors Capacitive Proximity Sensors FEATURES ɀ Senses all materials ɀ Threaded 18 mm diameter metal housings ɀ Threaded 30 mm diameter metal and plastic housings ɀ Sealed to IP 65 and IP 67 for industrial environments ɀ Shielded and unshielded sensing
|
Original
|
PDF
|
|
SV220 120
Abstract: SV125 230 volt ac overvoltage protection SV120230 5 volt dpdt 8 pin relay sv micro SV220 SV225 sv relays 12 Volt DPDT Relay
Text: Level Sensors Amplifier, Conductive Types SV 120/220, SV 125/225 Charging • • • • • • • SV 120/220 Level control for conductive liquids Max.-min. control of CHARGING SV 120/220: Fixed sensitivity SV 125/225: Adjustable sensitivity 10 A SPDT or 8 A DPDT output relay
|
Original
|
PDF
|
|
Untitled
Abstract: No abstract text available
Text: Level Sensors Conductive Types VT, VTI • • • • • • Product Description Level sensor for measuring the level of conductive liquids, i.e. max./min. control of charging for discharging. The function is determined by the amplifier relay used. The sensors are delivered with
|
Original
|
PDF
|
228/1-Gx"
228/1-G
S195/196,
S1961,
|
sv110 230 level control
Abstract: SV110 SV215 230 SV110024 1SV110 SV210 5 volt dpdt 8 pin relay "Level control relay" SV215 230 volt ac overvoltage protection
Text: Level Sensors Amplifier, Conductive Types SV 110/210, SV 115/215 Discharging • • • • • • • SV 110/210 Level control for conductive liquids Max.-min. control of DISCHARGING SV 110/210: Fixed sensitivity SV 115/225: Adjustable sensitivity 10 A SPDT or 8 A DPDT output relay
|
Original
|
PDF
|
|
Untitled
Abstract: No abstract text available
Text: Conductive Sensors Level Probes Types VT, VTI • • • • • • Excellent resistance to chemicals Teflon housing 1 to 4 electrodes Isolated teflon or unisolated electrodes Cable connection 1 1/2” pipe thread according to ISO 228/1-Gx” Product Description
|
Original
|
PDF
|
228/1-Gxâ
228/1-G
S195/196,
S1961,
|
S 196 156 230
Abstract: S196 S 195 166 230 datasheet transistor S196 MARKING S196 S196166 166 relay transistor s196 S195 S411
Text: Level Sensors Amplifier, Conductive Types S195, S196 Charging/Discharging • Level control for conductive liquids • Max.-min. control of charging/discharging • Selection of charging or discharging by a switch at the front of the system • S195: Fixed sensitivity
|
Original
|
PDF
|
From15
S 196 156 230
S196
S 195 166 230
datasheet transistor S196
MARKING S196
S196166
166 relay
transistor s196
S195
S411
|
S 196 156 230
Abstract: 156 relay datasheet transistor S196 transistor s196 s196 S196166 S411 relay 5 pin out diagram 5 pin out relay diagram 166 relay
Text: Level Sensors Amplifier, Conductive Types S195, S196 Charging/Discharging • Level control for conductive liquids • Max.-min. control of charging/discharging • Selection of charging or discharging by a switch at the front of the system • S195: Fixed sensitivity
|
Original
|
PDF
|
From15
S 196 156 230
156 relay
datasheet transistor S196
transistor s196
s196
S196166
S411
relay 5 pin out diagram
5 pin out relay diagram
166 relay
|
Untitled
Abstract: No abstract text available
Text: Conductive Sensors Level Probes Types CLH • • • • • Flexible conductive level probe 1 to 5 electrodes User defined electrode length Isolated or unisolated electrodes 1 1/2” pipe thread according to ISO 228/1-G11/2A Product Description Ordering Key
|
Original
|
PDF
|
228/1-G11/2A
|
Untitled
Abstract: No abstract text available
Text: LSK x2x Conductive Level Sensor Wetted parts in acid-proof, stainless steel and PEEK Compact, food compatible, hygienic design 3A approved, FDA and EHEDG compliant Process temperature -20.140°C LSK320 Optimised flow geometry Millimetre precise switch point
|
Original
|
PDF
|
LSK320
LSK420
LKP100)
LKP100
LSK32x,
LSK42x
LSK52x
UK/2012-08-29
|
972AA4WP-C3R-L-030
Abstract: capacitive sensor water level detection capacitive level sensor 972AB4WP-C3R-L-030
Text: Proximity Sensors 972/973 Series 30 mm Diameter Relay Output Cylindrical Sensor 2-Wire DC, 2-Wire AC/DC Type FEATURES • Integral SPDT 6 amp relay • High output current capability - up to 6 amps • N.O. and N.C. contacts in the same unit • Isolated outputs
|
OCR Scan
|
PDF
|
MSS1S30
972AA4WP-C3R-L-030
capacitive sensor water level detection
capacitive level sensor
972AB4WP-C3R-L-030
|