Untitled
Abstract: No abstract text available
Text: High Performance Relays and Power Contactors KILOVAC — Protective Relays DIN Rail or Screw Mounted Voltage Sensitive Relays Paralleling Relays Current Sensitive Relays ANSI/IEEE C37.90-1978 UL File No. E58048 CSA File No. LR61158 DIN EN50022-35 Frequency Sensitive Relays
|
Original
|
PDF
|
E58048
LR61158
EN50022-35
WD2759-XXX
WD2759
|
C37-90
Abstract: No abstract text available
Text: Frequency Sensitive Relays WILMAR Protective Relays – WOF & WUF Series Function: 81 O/U • ANSI/IEEE C37.90-1978 • UL file No. E58048 • CSA file No. LR61158 Application: The output contacts of frequency relays are energized when the frequency exceeds the adjustable set
|
Original
|
PDF
|
E58048
LR61158
400Hz.
28VDC
C37-90
|
d100
Abstract: No abstract text available
Text: Voltage Sensitive Relays WILMAR Protective Relays – D100X Series, Close Differential Function: • ANSI/IEEE C37.90-1978 • UL file No. E58048 • CSA file No. LR61158 0.5 Close Differential Relays are voltage sensitive. The pick-up and drop-out voltage settings are independently adjustable, which allows precise setting of the
|
Original
|
PDF
|
D100X
E58048
LR61158
D100-3X
D100-4X
D100-8X
D100-5X
D100-7X
d100
|
380 volt 50 hz
Abstract: time curves E58048
Text: Frequency Sensitive Relays WILMAR Protective Relays – WOUF Series, Over/Underfrequency Function: 81 O/U • ANSI/IEEE C37.90-1978 • UL file No. E58048 • CSA file No. LR61158 S TRIP AL S EWS N I R M TER 32 SC #6 - 3 The output contacts of frequency relays are energized when the frequency exceeds the adjustable
|
Original
|
PDF
|
E58048
LR61158
400Hz.
WOUF-12-5060-T
Hz400-450
380 volt 50 hz
time curves
E58048
|
LR61158
Abstract: E58048
Text: Frequency Sensitive Relays WILMAR Protective Relays – 20-050-19 Series Voltage/Frequency Function: 27/81 • ANSI/IEEE C37.90-1978 • UL file No. E58048 • CSA file No. LR61158 #6 - 32 STUDS 6 PLACES 4 1/2 The output contacts of frequency relays are energized when the frequency exceeds the adjustable set
|
Original
|
PDF
|
E58048
LR61158
400Hz.
20-050-19X
LR61158
E58048
|
"reverse Power Relays"
Abstract: 723 SAMPLE CIRCUITS
Text: Reverse Power Relays WILMAR Protective Relays – 700 Series Function: 32 • ANSI/IEEE C37.90-1978 TERMINAL STRIPS #6 - 32 SCREWS • UL file No. E58048 • CSA file No. LR61158 Several types of Reverse Power Relays are available including relays sensitive to reverse reactive power
|
Original
|
PDF
|
E58048
LR61158
"reverse Power Relays"
723 SAMPLE CIRCUITS
|
WSYN
Abstract: phase angle detector paralleling relay preset Potentiometers 24DC 48DC
Text: Paralleling Relays WILMAR Protective Relays – WSYN Series Function: 25 • ANSI/IEEE C37.90-1978 TERMINAL STRIPS #6 - 32 SCREWS • UL file No. E58048 • CSA file No. LR61158 Operation: A. The output relay will energize when all three of the following conditions are met:
|
Original
|
PDF
|
E58048
LR61158
WSYN-50-120-12DC-A
120AC
230AC
380AC
125DC
460AC
WSYN
phase angle detector
paralleling relay
preset Potentiometers
24DC
48DC
|
SINGLE TURN POTENTIOMETERS
Abstract: No abstract text available
Text: Voltage Sensitive Relays WILMAR Protective Relays – WUVT/WOVT Series Function: 27/59 • ANSI/IEEE C37.90-1978 TERMINAL STRIPS #6 - 32 SCREWS • UL file No. E58048 • CSA file No. LR61158 Undervoltage Models - The relay is energized at normal voltage, N.C. contacts will open and N.O.
|
Original
|
PDF
|
E58048
LR61158
SINGLE TURN POTENTIOMETERS
|
WUV-1-120
Abstract: No abstract text available
Text: Voltage Sensitive Relays WILMAR Protective Relays – WUV/WOV Series Function: 27/59 • ANSI/IEEE C37.90-1978 • UL file No. E58048 • CSA file No. LR61158 TERMINAL STRIPS #6 - 32 SCREWS Voltage sensitive relays are available for both AC and DC applications for over/undervoltage protection.
|
Original
|
PDF
|
E58048
LR61158
125VDC,
WUV-1-120
|
phase failure relay
Abstract: No abstract text available
Text: Phase Failure Relays WILMAR Protective Relays – 1000 Series Function: 47 • ANSI/IEEE C37.90-1978 TERMINAL STRIPS #6 - 32 SCREWS • UL file No. E58048 • CSA file No. LR61158 Phase failure relays protect motors, equipment and personnel from damage or injury caused by open
|
Original
|
PDF
|
E58048
LR61158
1004X
phase failure relay
|
2110-5K
Abstract: power transformers fault 1260k
Text: Ground Fault Relays WILMAR Protective Relays – WGD Series – Floating Ground Function: • ANSI/IEEE C37.90-1978 • UL file No. E58048 • CSA file No. LR61158 TERMINAL STRIPS #6 - 32 SCREWS 3.0 WILMAR Ground Fault Detectors are used to sense leakage current to ground in power transformers and generators. They are available for both AC and DC systems.
|
Original
|
PDF
|
E58048
LR61158
208-120AC
220-120AC
230-120AC
240-120AC
380-120AC
400-120AC
416-120AC
440-120AC
2110-5K
power transformers fault
1260k
|
CII Technologies relay
Abstract: en 50022-35 4422 datasheet relay phase control 3 phase voltage relay
Text: Phase Sequence Relays Kilovac - WD47-XXX Phase Sequence Relay Din Rail Mounting Function: 47 • ANSI/IEEE C37.90-1978 • UL file No. E58048 • DIN EN50022-35 Operation: WD47 Series phase sequence relays are designed to monitor the correct phase rotation and loss of
|
Original
|
PDF
|
WD47-XXX
E58048
EN50022-35
CII Technologies relay
en 50022-35
4422 datasheet
relay phase control
3 phase voltage relay
|
phase failure relay
Abstract: No abstract text available
Text: Current Balance Relays WILMAR Protective Relays – WCB Series Function: 60 or 87 • ANSI/IEEE C37.90-1978 TERMINAL STRIPS #6 - 32 SCREWS • UL file No. E58048 • CSA file No. LR61158 Current Balance Relays are designed to sense unbalanced current flow in a three phase system. The
|
Original
|
PDF
|
E58048
LR61158
phase failure relay
|
D101
Abstract: D101X differential relay D101-6X
Text: Voltage Sensitive Relays WILMAR Protective Relays – D101X Series, 3 Phase Adjustable, Close Differential Function: • ANSI/IEEE C37.90-1978 • UL file No. E58048 • CSA file No. LR61158 #6 - 32 STUDS 10 PLACES Close Differential Relays are voltage sensitive. The
|
Original
|
PDF
|
D101X
E58048
LR61158
D101X
D101-6X
D101-4X
D101-10X
D101-7X
D101
differential relay
D101-6X
|
|
C37-90B
Abstract: E58048
Text: Current Sensitive Relays WILMAR Protective Relays – WC1 & WCT1 Series, Overcurrent Function: 50/51 • ANSI/IEEE C37.90-1978 TERMINAL STRIPS #6 - 32 SCREWS • UL file No. E58048 • CSA file No. LR61158 Current sensitive relays are available for single and
|
Original
|
PDF
|
E58048
LR61158
WCT3-48DC-5A
C37-90B
E58048
|
"reverse Power Relays"
Abstract: 700TD 730TD
Text: Reverse Power Relays WILMAR Protective Relays – 700 Series w/ Adjustable Time Delay Function: 32 • ANSI/IEEE C37.90-1978 • UL file No. E58048 • CSA file No. LR61158 TERMINAL STRIPS #6 - 32 SCREWS 3.0 Several types of Reverse Power Relays are available
|
Original
|
PDF
|
E58048
LR61158
710TD
"reverse Power Relays"
700TD
730TD
|
500w pioneer power amp circuit diagram
Abstract: pioneer PAL 010a 500w audio amplifier circuit diagram 500w power amplifier circuit diagram V23148 -B0010-A101 18V circuit diagram electronic ballast for 40W tube 12v 300W AUDIO AMPLIFIER CIRCUIT DIAGRAM ups circuit schematic diagram 1000w PAL 007 pioneer 1000w class d circuit diagram schematics
Text: Relays, Contactors, Timers, Transformers and Circuit Breakers for General Purpose Industrial & Commercial Applications This technical databook includes specification information for a broad selection of components. Electromechanical relays, contactors, timers, solid state relays, input/output modules, sensors, protective relays,
|
Original
|
PDF
|
that5-926-55-05
500w pioneer power amp circuit diagram
pioneer PAL 010a
500w audio amplifier circuit diagram
500w power amplifier circuit diagram
V23148 -B0010-A101 18V
circuit diagram electronic ballast for 40W tube
12v 300W AUDIO AMPLIFIER CIRCUIT DIAGRAM
ups circuit schematic diagram 1000w
PAL 007 pioneer
1000w class d circuit diagram schematics
|
500w pioneer power amp circuit diagram
Abstract: LG color tv Circuit Diagram schematics 500w pioneer power amp circuit diagram schematic schematic DIAGRAM AVR 150 kva GENERATOR Relay schrack RU magnetic Contactor wiring diagrams and float switch schrack V23148 src 06vdc agastat 7022 schematic DIAGRAM AVR 500 kva GENERATOR
Text: Relays, Contactors, Timers, Transformers and Circuit Breakers For General Purpose Applications TYCO ELECTRONICS CORPORATION WWW.TYCOELECTRONICS.COM Catalog 1308242 Revised 3-03 AGASTAT AXICOM KILOVAC OEG P&B PRODUCTS UNLIMITED SCHRACK Catalog 1308242 Revised 3-03
|
Original
|
PDF
|
|
Reverse Power Relay
Abstract: "reverse Power Relays" paralleling relay over current relay relay 112 SPDT DIN rail relay 166 relay 4 change over relays 9 Volt DPDT Relay double change over relay
Text: Catalog 1308242 Issued 3-03 PDF Rev. 6/07 KILOVAC WD series DIN Rail or Screw Mounted Protective Relays • • • • • • WD25 Paralleling (Synch Check) Relays WD2759 Over/undervoltage Relays WD32 Reverse Power Relays WD47 Phase Sequence Relays WD5051 Single- or Three-Phase Overcurrent Relays
|
Original
|
PDF
|
WD2759
WD5051
WD81OU
E58048
EN50022-35
54VDC
100-200VDC
100-140VAC.
Reverse Power Relay
"reverse Power Relays"
paralleling relay
over current relay
relay 112
SPDT DIN rail relay
166 relay
4 change over relays
9 Volt DPDT Relay
double change over relay
|
Untitled
Abstract: No abstract text available
Text: ti/ca Voltage Sensitive Relays Electronics W ILMAR Protective Relays - D100X Series, Close Differential Function: ANSI/IEEE C37.90-1978 UL file No. E58048 CSA file No. LR61158 Close Differential Relays are voltage sensitive. The pick-up and drop-out voltage settings are indepen
|
OCR Scan
|
PDF
|
D100X
E58048
LR61158
200mSec.
|
Untitled
Abstract: No abstract text available
Text: tijca Paralleling Relays Electronics WILMAR Protective Relays-1 8 00 Series Function: 25 ANSI/IEEE C37.90-1978 UL file No. E58048 CSA file No. LR61158 #6 - 32 STUDS 6 PLACES <§ <£> Application: These relays are designed for automatic paralleling synchronizing of generators. The relays sense the
|
OCR Scan
|
PDF
|
E58048
LR61158
|