transmit g1
Abstract: No abstract text available
Text: BACK L4M Device Level 4 Mapper TXC-03456 DATA SHEET Preliminary DESCRIPTION • Maps an asynchronous 139.264 Mbit/s tributary into an AU-4/VC-4 STS-3c/SPE. • Nibble or byte 139.264 Mbit/s line interface - G.751 receive and transmit performance monitoring frame alignment, distant alarm
|
Original
|
PDF
|
TXC-03456
TXC-03456-MB
transmit g1
|
transmit g1
Abstract: EDV54-120-31 751 sage
Text: L4M Device Level 4 Mapper TXC-03456 DATA SHEET Preliminary DESCRIPTION • Maps an asynchronous 139.264 Mbit/s tributary into an AU-4/VC-4 STS-3c/SPE. • Nibble or byte 139.264 Mbit/s line interface - G.751 receive and transmit performance monitoring frame alignment, distant alarm
|
Original
|
PDF
|
TXC-03456
TXC-03456-MB
transmit g1
EDV54-120-31
751 sage
|
sage quadrature hybrid
Abstract: No abstract text available
Text: 3dB TEMLINE Hybrid Couplers 3dB TEMLINE Hybrid Couplers Series High Power, Octave Band, Quadrature Designs Features • Average Power Rating 1,000 Watts, Normalized at 1 GHz • 1 dB Maximum Unbalance² • Meet MIL-E-5400 Class 3 or Equivalent • Screenable to MIL-P-23971 or Equivalent
|
Original
|
PDF
|
MIL-E-5400
MIL-P-23971
sage quadrature hybrid
|
lnk500 to equivalent ic
Abstract: LNK500 SPRU099 SPRU131 SPRU302 XDS510
Text: TMS320C54x Optimizing C Compiler User’s Guide Literature Number: SPRU103D December 1999 Printed on Recycled Paper IMPORTANT NOTICE Texas Instruments and its subsidiaries TI reserve the right to make changes to their products or to discontinue any product or service without notice, and advise customers to obtain the latest version of relevant information
|
Original
|
PDF
|
TMS320C54x
SPRU103D
lnk500 to equivalent ic
LNK500
SPRU099
SPRU131
SPRU302
XDS510
|
Relay NAIS Ds
Abstract: E3252 SG 2368 ATA 2388 ic 393 NAIS tf relay tes 5-2422
Text: áç XRT72L50 SINGLE CHANNEL DS3/E3 FRAMER IC WITH HDLC CONTROLLER OCTOBER 2003 REV. 1.2.1 GENERAL DESCRIPTION The XRT72L50, single Channel DS3/E3 Framer IC is designed to accept user data from the Terminal Equipment and insert this data into the payload bitfields within an outbound DS3/E3 Data Stream. Further, the Framer IC is also designed to receive an inbound DS3/E3 Data Stream from the Remote Terminal Equipment and extract out the user data.
|
Original
|
PDF
|
XRT72L50
XRT72L50,
XRT72L50
DS3-M13,
XRT72L50IQ-F
PQFP100
01-Aug-09
Relay NAIS Ds
E3252
SG 2368
ATA 2388
ic 393
NAIS tf relay
tes 5-2422
|
dmo 365 r
Abstract: ATA 2388 dmo 265 r datasheet relay NAIS 5v 5 pin marx and generator IC ATA 2388 RELAY AG 105 21 Esart NAIS 210 RELAY DS3-M13
Text: áç XRT72L50 SINGLE CHANNEL DS3/E3 FRAMER IC WITH HDLC CONTROLLER OCTOBER 2003 REV. 1.2.1 GENERAL DESCRIPTION The XRT72L50, single Channel DS3/E3 Framer IC is designed to accept user data from the Terminal Equipment and insert this data into the payload bitfields within an outbound DS3/E3 Data Stream. Further, the Framer IC is also designed to receive an inbound DS3/E3 Data Stream from the Remote Terminal Equipment and extract out the user data.
|
Original
|
PDF
|
XRT72L50
XRT72L50,
XRT72L50
DS3-M13,
dmo 365 r
ATA 2388
dmo 265 r
datasheet relay NAIS 5v 5 pin
marx and generator
IC ATA 2388
RELAY AG 105 21
Esart
NAIS 210 RELAY
DS3-M13
|
dmo 265 r
Abstract: t59b
Text: xr XRT72L50 SINGLE CHANNEL DS3/E3 FRAMER IC WITH HDLC CONTROLLER MAY 2003 REV. 1.2.0 GENERAL DESCRIPTION The XRT72L50, single Channel DS3/E3 Framer IC is designed to accept user data from the Terminal Equipment and insert this data into the payload bitfields within an outbound DS3/E3 Data Stream. Further, the Framer IC is also designed to receive an inbound DS3/E3 Data Stream from the Remote Terminal Equipment and extract out the user data.
|
Original
|
PDF
|
XRT72L50
XRT72L50,
XRT72L50
DS3-M13,
XRT72LCorporation
dmo 265 r
t59b
|
ic 381
Abstract: 147il dmo 365 rn Ic 384
Text: áç XRT7250 PRELIMINARY DS3/E3 FRAMER IC OCTOBER 2000 REV. P1.0.7 GENERAL DESCRIPTION The XRT7250 DS3/E3 Framer IC is designed to accept “User Data” from the Terminal Equipment and insert this data into the “payload” bit-fields within an “outbound” DS3/E3 Data Stream. Further, the Framer
|
Original
|
PDF
|
XRT7250
XRT7250
DS3-M13,
ic 381
147il
dmo 365 rn
Ic 384
|
dmo 365 r
Abstract: IC A 2388 DS3-M13 IC TX 434 dmo 365 rn RT7300 4T701 XRT7250 XRT7250IQ 43a 244
Text: áç XRT7250 DS3/E3 FRAMER IC DECEMBER 2000 REV. 1.1.0 GENERAL DESCRIPTION The XRT7250 DS3/E3 Framer IC is designed to accept “User Data” from the Terminal Equipment and insert this data into the “payload” bit-fields within an “outbound” DS3/E3 Data Stream. Further, the Framer
|
Original
|
PDF
|
XRT7250
XRT7250
DS3-M13,
dmo 365 r
IC A 2388
DS3-M13
IC TX 434
dmo 365 rn
RT7300
4T701
XRT7250IQ
43a 244
|
dmo 365 rn
Abstract: DMO36 dmo 365 r IC TX 434 HDB3 AMI ENCODER DECODER t90 series DS3-M13 XRT7250 XRT7250IQ difference between 8051 and 8052 microcontroller
Text: áç XRT7250 PRELIMINARY DS3/E3 FRAMER IC MARCH 2000 REV. P1.0.5 GENERAL DESCRIPTION The XRT7250 DS3/E3 Framer IC is designed to accept “User Data” from the Terminal Equipment and insert this data into the “payload” bit-fields within an “outbound” DS3/E3 Data Stream. Further, the Framer
|
Original
|
PDF
|
XRT7250
XRT7250
DS3-M13,
dmo 365 rn
DMO36
dmo 365 r
IC TX 434
HDB3 AMI ENCODER DECODER
t90 series
DS3-M13
XRT7250IQ
difference between 8051 and 8052 microcontroller
|
dmo 365 r
Abstract: ic 381 RT7300 IC A 2388 178AP DS3-M13 XRT7250 XRT7250IQ xrt7250iq100
Text: áç XRT7250 DS3/E3 FRAMER IC MARCH 2001 REV. 1.1.1 GENERAL DESCRIPTION The XRT7250 DS3/E3 Framer IC is designed to accept “User Data” from the Terminal Equipment and insert this data into the “payload” bit-fields within an “outbound” DS3/E3 Data Stream. Further, the Framer
|
Original
|
PDF
|
XRT7250
XRT7250
DS3-M13,
dmo 365 r
ic 381
RT7300
IC A 2388
178AP
DS3-M13
XRT7250IQ
xrt7250iq100
|
Untitled
Abstract: No abstract text available
Text: áç XRT72L50 PRELIMINARY SINGLE CHANNEL DS3/E3 FRAMER IC WITH HDLC CONTROLLER JANUARY 2001 REV. P1.1.3 GENERAL DESCRIPTION The XRT72L50, single Channel DS3/E3 Framer IC is designed to accept “User Data” from the Terminal Equipment and insert this data into the “payload” bitfields within an “outbound” DS3/E3 Data Stream. Further, the Framer IC is also designed to receive an “inbound” DS3/E3 Data Stream from the Remote Terminal Equipment and extract out the “User Data”.
|
Original
|
PDF
|
XRT72L50
XRT72L50,
XRT72L50
DS3-M13,
|
Rx1302
Abstract: r4363 dmo 265
Text: áç XRT72L50 PRELIMINARY SINGLE CHANNEL DS3/E3 FRAMER IC WITH HDLC CONTROLLER JANUARY 2001 REV. P1.1.2 GENERAL DESCRIPTION The XRT72L50, single Channel DS3/E3 Framer IC is designed to accept “User Data” from the Terminal Equipment and insert this data into the “payload” bitfields within an “outbound” DS3/E3 Data Stream. Further, the Framer IC is also designed to receive an “inbound” DS3/E3 Data Stream from the Remote Terminal Equipment and extract out the “User Data”.
|
Original
|
PDF
|
XRT72L50
XRT72L50,
XRT72L50
DS3-M13,
Rx1302
r4363
dmo 265
|
IN134
Abstract: ic 393 datasheet relay NAIS 5v 5 pin 74hct00 dmo 365 r NAIS 210 RELAY NAIS Relay 5v t90 series 0X13 DS3-M13
Text: áç XRT72L52 PRELIMINARY TWO CHANNEL DS3/E3 FRAMER IC WITH HDLC CONTROLLER JANUARY 2001 REV. P1.1.3 GENERAL DESCRIPTION The XRT72L52, 2 Channel DS3/E3 Framer IC is designed to accept “User Data” from the Terminal Equipment and insert this data into the “payload” bitfields within an “outbound” DS3/E3 Data Stream. Further, the Framer IC is also designed to receive an “inbound” DS3/E3 Data Stream from the Remote Terminal Equipment and extract out the “User Data”.
|
Original
|
PDF
|
XRT72L52
XRT72L52,
XRT72L52
DS3-M13,
IN134
ic 393
datasheet relay NAIS 5v 5 pin
74hct00
dmo 365 r
NAIS 210 RELAY
NAIS Relay 5v
t90 series
0X13
DS3-M13
|
|
NAIS 210 RELAY
Abstract: ic 393 k 4213 0X13 DS3-M13 XRT72L52
Text: áç XRT72L52 PRELIMINARY TWO CHANNEL DS3/E3 FRAMER IC WITH HDLC CONTROLLER JANUARY 2001 REV. P1.1.2 GENERAL DESCRIPTION The XRT72L52, 2 Channel DS3/E3 Framer IC is designed to accept “User Data” from the Terminal Equipment and insert this data into the “payload” bitfields within an “outbound” DS3/E3 Data Stream. Further, the Framer IC is also designed to receive an “inbound” DS3/E3 Data Stream from the Remote Terminal Equipment and extract out the “User Data”.
|
Original
|
PDF
|
XRT72L52
XRT72L52,
XRT72L52
DS3-M13,
NAIS 210 RELAY
ic 393
k 4213
0X13
DS3-M13
|
dmo 465
Abstract: dmo 365 r 74hct00 NAIS 210 RELAY 0X13 DS3-M13 XRT72L54 relay NAIS 5v 5 pin BIP 109 intel 4702
Text: áç XRT72L54 PRELIMINARY FOUR CHANNEL DS3/E3 FRAMER IC WITH HDLC CONTROLLER JANUARY 2001 REV. P1.1.2 GENERAL DESCRIPTION The XRT72L54, 4 Channel DS3/E3 Framer IC is designed to accept “User Data” from the Terminal Equipment and insert this data into the “payload” bitfields within an “outbound” DS3/E3 Data Stream. Further, the Framer IC is also designed to receive an “inbound” DS3/E3 Data Stream from the Remote Terminal Equipment and extract out the “User Data”.
|
Original
|
PDF
|
XRT72L54
XRT72L54,
XRT72L54
DS3-M13,
dmo 465
dmo 365 r
74hct00
NAIS 210 RELAY
0X13
DS3-M13
relay NAIS 5v 5 pin
BIP 109
intel 4702
|
r4363
Abstract: CP Clare RELAY dmo 465 IC 404
Text: áç XRT72L53 PRELIMINARY THREE CHANNEL DS3/E3 FRAMER IC WITH HDLC CONTROLLER JANUARY 2001 REV. P1.1.6 GENERAL DESCRIPTION The XRT72L53, 3 Channel DS3/E3 Framer IC is designed to accept User Data from the Terminal Equipment and insert this data into the Payload bit-fields
|
Original
|
PDF
|
XRT72L53
XRT72L53,
XRT72L53
DS3-M13,
r4363
CP Clare RELAY
dmo 465
IC 404
|
B628
Abstract: datasheet relay NAIS 5v 5 pin iC 458 XRT72L58 "Encoder IC" NAIS 210 RELAY octal tri state buffer ic DS3-M13 XRT72L58IB TTB-11
Text: áç XRT72L58 PRELIMINARY EIGHT CHANNEL DS3/E3 FRAMER IC WITH HDLC CONTROLLER JANUARY 2001 REV. P1.1.2 GENERAL DESCRIPTION The XRT72L58 Octal DS3/E3 Framer is designed to accept “User Data” from the Terminal Equipment and insert this data into the “payload” bit-fields within an
|
Original
|
PDF
|
XRT72L58
XRT72L58
DS3-M13,
B628
datasheet relay NAIS 5v 5 pin
iC 458
"Encoder IC"
NAIS 210 RELAY
octal tri state buffer ic
DS3-M13
XRT72L58IB
TTB-11
|
Untitled
Abstract: No abstract text available
Text: Philips C om pon ents-Signetics Application Specific Product Section 3 - 80C51 family derivatives 8XC751 O V ER VIEW 8XC751 • Idle mode The Sign etics 6 3C 751/87C 751 offers the a d vantages of the S C 8 0 C 5 1 architecture in a small package a nd at a low cost. T h is micro
|
OCR Scan
|
PDF
|
80C51
8XC751
8XC751
751/87C
16-bit
|
Untitled
Abstract: No abstract text available
Text: L4M Device Level 4 Mapper TXC-03456 DATA SHEET Preliminary . = • Maps an asynchronous 139.264 Mbit/s tributary into an AU-4/VC-4 STS-3c/SPE. • Nibble or byte 139.264 Mbit/s line interface - G.751 receive and transmit performance
|
OCR Scan
|
PDF
|
TXC-03456
DM220
TXC-03456-MB
|
TS12864
Abstract: No abstract text available
Text: L4M Device Level 4 Mapper TXC-03456 DATA SHEET Preliminary = • Maps an asynchronous 139.264 Mbit/s tributary into an AU-4/VC-4 STS-3c/SPE. • Nibble or byte 139.264 Mbit/s line interface - G.751 receive and transmit performance monitoring frame alignment, distant alarm
|
OCR Scan
|
PDF
|
TXC-03456
TXC-03456-MB
TS12864
|
M68020
Abstract: M68000 MC68020 MC68EC020 731 motorola INDEX33 memory110
Text: 9 /29/95 S E C TIO N 1: O V E R V IE W UM Rev 1 TABLE OF CONTENTS Paragraph Number Title Page Number Section 1 Introduction 1.1 1.2 1.3 1.4 1.5 1.5.1 1.5.2 1.6 1.7 Features. 1-2
|
OCR Scan
|
PDF
|
MC68020
MC68EC020
M68020
M68000
731 motorola
INDEX33
memory110
|
GG1Q
Abstract: No abstract text available
Text: 1.0 Product Description 1.1 Introduction Figure 1-1 is a detailed block diagram o f the Bt8222. For transmission from the host system, octet-wide data is input from the UTOPIA or FIFO ports. The host data is assembled into ATM cells and then formatted for serial line transmission
|
OCR Scan
|
PDF
|
Bt8222.
GG1Q
|
ssy 1920
Abstract: L8222
Text: llOii 1.0 Product Description - The Bt8222 ATM Physical Interface PHY) device is a receiver/transmitter which converts several types of frames to ATM cells and vice versa. The device contains framers for DS3, E3, E4, STS-1, STS-3c nd STM-1. This chapter provides an
|
OCR Scan
|
PDF
|
Bt8222
Bt8222,
Bt8222.
int103
L8222
Bt8222
ssy 1920
|