7116-4103-02
Abstract: 7116-4102-02 7116-4102-08 7116410302 connector yazaki 7116 7283-5689-30 Yazaki YAZAKI 7283 yazaki terminals
Text: Lamp Socket FEATURES • • • Socket designed for use with SAE defined peanut bulb 921, 922, 168, 194 USCAR class III (-40°C - 125°C) Sockets available in both axial and right angle versions to best accommodate vehicle packaging restrictions BENEFITS
|
Original
|
48kPa
28kPa
7116-4103-02
7116-4102-02
7116-4102-08
7116410302
connector yazaki
7116
7283-5689-30
Yazaki
YAZAKI 7283
yazaki terminals
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Se a le d Y ESC 1 .5 x 0 .8 SPECI FI CAT I ON S Connector Male Terminal Female Terminal Operating Temperature Range Voltage Drop Isolation resistance Dielectric Resistance Material Applicable Wire Size Terminal Pitch Sealing Performance Air Leak Pressure
|
Original
|
500VDC,
1000VAC
22AWG
16AWG
48kPa
28kPa
|
PDF
|
7114-4152
Abstract: 7114-4152-02 7116-4152-02 711641 7114-4150-02 YAZAKI female Terminal 2.8 YAZAKI female Terminal 28
Text: Sealed YESC 2.8 x 0.8 SPECIFICATIONS Connector Male Terminal Female Terminal Operating Temperature Range Voltage Drop Isolation resistance Dielectric Resistance Material Applicable Wire Size Terminal Pitch Sealing Performance Air Leak Pressure Terminal-to-Connector Retention Force
|
Original
|
500VDC,
1000VAC
22AWG
14AWG
48kPa
28kPa
7114-4152
7114-4152-02
7116-4152-02
711641
7114-4150-02
YAZAKI female Terminal 2.8
YAZAKI female Terminal 28
|
PDF
|
7114-4721-02
Abstract: 7114-4720-02 7116-4720-02
Text: Sealed YESC 0.64 x 0.64 SPECIFICATIONS Material Connector Male Terminal Female Terminal Operating Temperature Range Voltage Drop Isolation resistance Dielectric Resistance Applicable Wire Size Terminal Pitch Sealing Performance Air Leak Pressure Terminal-to-Connector Retention Force
|
Original
|
500VDC,
1000VAC
22AWG
18AWG
48kPa
28kPa
7114-4721-02
7114-4720-02
7116-4720-02
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Fue l I nje c t or Conne c t or DESCRI PT I ON A 2 way 1.5 female YESC for various fuel injector types with flexibility to be used for other applications. FEAT U RES • Sealed 1.5 mm YESC terminals • USCAR class III -40°C - 125°C • Pre-set TPA •
|
Original
|
500VDC,
|
PDF
|
7116-4142-02
Abstract: 7116414202 7116414002 7116-4141-02 7114-4 711641 7116-4140-02 7114-4141-02 Yazaki 7114-4140-02
Text: Sealed YESC 6.3 x 0.8 SPECIFICATIONS Connector Male Terminal Female Terminal Operating Temperature Range Voltage Drop Isolation resistance Dielectric Resistance Material Applicable Wire Size Terminal Pitch Sealing Performance Air Leak Pressure Terminal-to-Connector Retention Force
|
Original
|
500VDC,
1000VAC
20AWG
12AWG
48kPa
28kPa
7116-4142-02
7116414202
7116414002
7116-4141-02
7114-4
711641
7116-4140-02
7114-4141-02
Yazaki 7114-4140-02
|
PDF
|
fuel injector
Abstract: 7116-4103-02 7116-4102-08 7116410302 7116-4102-02 7283-5967-30 71164 USCAR 7116410202 yazaki terminals
Text: Fuel Injector Connector DESCRIPTION A 2 way 1.5 female YESC for various fuel injector types with flexibility to be used for other applications. FEATURES • Sealed 1.5 mm YESC terminals • USCAR class III -40°C - 125°C • Pre-set TPA • With and without cut-out
|
Original
|
22AWG
16AWG
48kPa
28kPa
fuel injector
7116-4103-02
7116-4102-08
7116410302
7116-4102-02
7283-5967-30
71164
USCAR
7116410202
yazaki terminals
|
PDF
|
7116-4152-02
Abstract: 7114-4152-02 7114-4150-02
Text: Se a le d Y ESC 2 .8 x 0 .8 SPECI FI CAT I ON S Connector Male Terminal Female Terminal Operating Temperature Range Voltage Drop Isolation resistance Dielectric Resistance Material Applicable Wire Size Terminal Pitch Sealing Performance Air Leak Pressure
|
Original
|
500VDC,
1000VAC
22AWG
14AWG
48kPa
28kPa
7116-4152-02
7114-4152-02
7114-4150-02
|
PDF
|
7116-4103-02
Abstract: 7116-4102-02 terminal 7114-4102-02 7114-4102-02 7116-4102-08 7116410302 7114-4102-08 7116410202 7114-4 711641
Text: Sealed YESC 1.5 x 0.8 SPECIFICATIONS Connector Male Terminal Female Terminal Operating Temperature Range Voltage Drop Isolation resistance Dielectric Resistance Material Applicable Wire Size Terminal Pitch Sealing Performance Air Leak Pressure Terminal-to-Connector Retention Force
|
Original
|
500VDC,
1000VAC
22AWG
16AWG
48kPa
28kPa
7116-4103-02
7116-4102-02
terminal 7114-4102-02
7114-4102-02
7116-4102-08
7116410302
7114-4102-08
7116410202
7114-4
711641
|
PDF
|
7283-5574-10
Abstract: No abstract text available
Text: s e a l e d c o n n e c t i o n s y s t e m Construction PRESET SECONDARY HOUSING LOCK HOUSING, M Specifications Connector Material HPA Male Terminal Copper Alloy Sn Plate Female Terminal Copper Alloy (Sn Plate) Operating Temperature Range Current Capacity
|
OCR Scan
|
500VDC,
1000VAC
22AWG
14AWG
35mm2
48kPa
X39899-J374.
7283-5574-10
|
PDF
|